This job view page is being replaced by Spyglass soon. Check out the new job view.
PRpohly: prow.sh: collect cluster logs
ResultFAILURE
Tests 1 failed / 48 succeeded
Started2021-05-11 13:14
Elapsed23m26s
Revisiond5f135239d64519310e3975b1e303fd3a6f6283c
Refs 149

Test Failures


test-shellcheck 0.00s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=test\-shellcheck$'
/usr/bin/docker

/home/prow/go/src/github.com/kubernetes-csi/external-provisioner/release-tools:
Using shellcheck 0.6.0 docker image.
Errors from shellcheck:

In ./prow.sh line 644:
            run kind export logs --name=csi-prow ${ARTIFACTS}/cluster-logs/$name
m                                                 ^----------^ SC2086: Double quote to prevent globbing and word splitting.
m                                                                           ^---^ SC2086: Double quote to prevent globbing and word splitting.

For more information:
  https://www.shellcheck.net/wiki/SC2086 -- Double quote to prevent globbing ...

Please review the above warnings. You can test via "./hack/verify-shellcheck"
If the above warnings do not make sense, you can exempt them from shellcheck
checking by adding the "shellcheck disable" directive
(https://github.com/koalaman/shellcheck/wiki/Directive#disable).

    
				
				Click to see stdout/stderrfrom junit_make_test.xml

Filter through log files | View test history on testgrid


Show 48 Passed Tests

Show 363 Skipped Tests

Error lines from build-log.txt

... skipping 100 lines ...
artifacts: ARTIFACTS=/logs/artifacts
Tue May 11 13:14:40 UTC 2021 go1.16.4 $ make all GOFLAGS_VENDOR=-mod=vendor BUILD_PLATFORMS=linux amd64; windows amd64 .exe; linux ppc64le -ppc64le; linux s390x -s390x; linux arm64 -arm64
./release-tools/verify-go-version.sh "go"
mkdir -p bin
echo 'linux amd64; windows amd64 .exe; linux ppc64le -ppc64le; linux s390x -s390x; linux arm64 -arm64' | tr ';' '\n' | while read -r os arch suffix; do \
	if ! (set -x; CGO_ENABLED=0 GOOS="$os" GOARCH="$arch" go build -mod=vendor -a -ldflags ' -X main.version=v2.2.0-8-gfab779138  -extldflags "-static"' -o "./bin/csi-provisioner$suffix" ./cmd/csi-provisioner); then \
		echo "Building csi-provisioner for GOOS=$os GOARCH=$arch failed, see error(s) above."; \
		exit 1; \
	fi; \
done
+ CGO_ENABLED=0 GOOS=linux GOARCH=amd64 go build -mod=vendor -a -ldflags  -X main.version=v2.2.0-8-gfab779138  -extldflags "-static" -o ./bin/csi-provisioner ./cmd/csi-provisioner
+ CGO_ENABLED=0 GOOS=windows GOARCH=amd64 go build -mod=vendor -a -ldflags  -X main.version=v2.2.0-8-gfab779138  -extldflags "-static" -o ./bin/csi-provisioner.exe ./cmd/csi-provisioner
+ CGO_ENABLED=0 GOOS=linux GOARCH=ppc64le go build -mod=vendor -a -ldflags  -X main.version=v2.2.0-8-gfab779138  -extldflags "-static" -o ./bin/csi-provisioner-ppc64le ./cmd/csi-provisioner
... skipping 128 lines ...

Please review the above warnings. You can test via "./hack/verify-shellcheck"
If the above warnings do not make sense, you can exempt them from shellcheck
checking by adding the "shellcheck disable" directive
(https://github.com/koalaman/shellcheck/wiki/Directive#disable).

make: *** [release-tools/build.make:260: test-shellcheck] Error 1
make: Target 'test' not remade because of errors.
ERROR: 'make test' failed
WARNING: 'make test' failed, proceeding anyway
Tue May 11 13:21:19 UTC 2021 go1.16.4 $ make container GOFLAGS_VENDOR=-mod=vendor
./release-tools/verify-go-version.sh "go"
mkdir -p bin
echo '' | tr ';' '\n' | while read -r os arch suffix; do \
	if ! (set -x; CGO_ENABLED=0 GOOS="$os" GOARCH="$arch" go build -mod=vendor -a -ldflags ' -X main.version=v2.2.0-8-gfab779138  -extldflags "-static"' -o "./bin/csi-provisioner$suffix" ./cmd/csi-provisioner); then \
		echo "Building csi-provisioner for GOOS=$os GOARCH=$arch failed, see error(s) above."; \
		exit 1; \
	fi; \
done
+ CGO_ENABLED=0 GOOS= GOARCH= go build -mod=vendor -a -ldflags  -X main.version=v2.2.0-8-gfab779138  -extldflags "-static" -o ./bin/csi-provisioner ./cmd/csi-provisioner
docker build -t csi-provisioner:latest -f Dockerfile --label revision=v2.2.0-8-gfab779138 .
Sending build context to Docker daemon    400MB

... skipping 27 lines ...
Step 7/7 : LABEL revision=v2.2.0-8-gfab779138
 ---> Running in 13367a51759a
Removing intermediate container 13367a51759a
 ---> 35284e9aa32f
Successfully built 35284e9aa32f
Successfully tagged csi-provisioner:latest
Tue May 11 13:22:13 UTC 2021 go1.16.4 $ curl --fail --location -o /home/prow/go/pkg/csiprow.Tdmn6ok21K/bin/kind https://github.com/kubernetes-sigs/kind/releases/download/v0.10.0/kind-linux-amd64
  % Total    % Received % Xferd  Average Speed   Time    Time     Time  Current
                                 Dload  Upload   Total   Spent    Left  Speed

  0     0    0     0    0     0      0      0 --:--:-- --:--:-- --:--:--     0
100   624  100   624    0     0   3073      0 --:--:-- --:--:-- --:--:--  3073

 38 7277k   38 2766k    0     0  4542k      0  0:00:01 --:--:--  0:00:01 4542k
100 7277k  100 7277k    0     0  10.3M      0 --:--:-- --:--:-- --:--:-- 58.7M
No kind clusters found.
INFO: kind-config.yaml:
... skipping 187 lines ...
do so (now or later) by using -b with the checkout command again. Example:

  git checkout -b <new-branch-name>

HEAD is now at af46c47c Merge pull request #97075 from adtac/apfe2e-5
Tue May 11 13:25:42 UTC 2021 go1.16.4 /home/prow/go/src/k8s.io/kubernetes$ git clean -fdx
Tue May 11 13:25:42 UTC 2021 go1.16.4 $ curl --fail --location https://dl.google.com/go/go1.15.linux-amd64.tar.gz
  % Total    % Received % Xferd  Average Speed   Time    Time     Time  Current
                                 Dload  Upload   Total   Spent    Left  Speed

  0     0    0     0    0     0      0      0 --:--:-- --:--:-- --:--:--     0
  1  115M    1 1743k    0     0  11.2M      0  0:00:10 --:--:--  0:00:10 11.1M
 25  115M   25 29.4M    0     0  24.4M      0  0:00:04  0:00:01  0:00:03 24.4M
 45  115M   45 52.9M    0     0  24.4M      0  0:00:04  0:00:02  0:00:02 24.4M
 78  115M   78 90.4M    0     0  28.7M      0  0:00:04  0:00:03  0:00:01 28.7M
 98  115M   98  113M    0     0  27.4M      0  0:00:04  0:00:04 --:--:-- 27.4M
100  115M  100  115M    0     0  26.6M      0  0:00:04  0:00:04 --:--:-- 27.1M
Tue May 11 13:25:46 UTC 2021 go1.15 $ make WHAT=test/e2e/e2e.test -C/home/prow/go/src/k8s.io/kubernetes
make: Entering directory '/home/prow/go/src/k8s.io/kubernetes'
make[1]: Entering directory '/home/prow/go/src/k8s.io/kubernetes'
... skipping 406 lines ...
[BeforeEach] [Testpattern: Dynamic PV (delayed binding)] topology
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:174
STEP: Creating a kubernetes client
May 11 13:29:40.463: INFO: >>> kubeConfig: /root/.kube/config
STEP: Building a namespace api object, basename topology
STEP: Waiting for a default service account to be provisioned in namespace
[It] should fail to schedule a pod which has topologies that conflict with AllowedTopologies
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/topology.go:192
May 11 13:29:40.544: INFO: Driver didn't provide topology keys -- skipping
[AfterEach] [Testpattern: Dynamic PV (delayed binding)] topology
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:175
May 11 13:29:40.545: INFO: Waiting up to 3m0s for all (but 0) nodes to be ready
STEP: Destroying namespace "topology-9773" for this suite.


S [SKIPPING] [0.097 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (delayed binding)] topology
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail to schedule a pod which has topologies that conflict with AllowedTopologies [It]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/topology.go:192

    Driver didn't provide topology keys -- skipping

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/topology.go:124
------------------------------
SSSSSSSSSSS
------------------------------
External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (filesystem volmode)] volumeMode 
  should fail to use a volume in a pod with mismatched mode [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:292

[BeforeEach] [Testpattern: Dynamic PV (filesystem volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (filesystem volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:174
STEP: Creating a kubernetes client
May 11 13:29:39.670: INFO: >>> kubeConfig: /root/.kube/config
STEP: Building a namespace api object, basename volumemode
May 11 13:29:40.289: INFO: No PodSecurityPolicies found; assuming PodSecurityPolicy is disabled.
STEP: Waiting for a default service account to be provisioned in namespace
[It] should fail to use a volume in a pod with mismatched mode [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:292
May 11 13:29:40.294: INFO: Creating resource for dynamic PV
May 11 13:29:40.294: INFO: Using claimSize:1Mi, test suite supported size:{ 1Mi}, driver(hostpath.csi.k8s.io) supported size:{ 1Mi} 
STEP: creating a StorageClass volumemode-8015-e2e-sc9zmgw
STEP: creating a claim
May 11 13:29:40.324: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iog88nd] to have phase Bound
May 11 13:29:40.352: INFO: PersistentVolumeClaim hostpath.csi.k8s.iog88nd found but phase is Pending instead of Bound.
May 11 13:29:42.355: INFO: PersistentVolumeClaim hostpath.csi.k8s.iog88nd found and phase=Bound (2.03146145s)
STEP: Creating pod
STEP: Waiting for the pod to fail
May 11 13:29:44.404: INFO: Deleting pod "pod-0c32cd81-bfaf-47d5-8bfd-892fbdf5ee02" in namespace "volumemode-8015"
May 11 13:29:44.411: INFO: Wait up to 5m0s for pod "pod-0c32cd81-bfaf-47d5-8bfd-892fbdf5ee02" to be fully deleted
STEP: Deleting pvc
May 11 13:29:52.416: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.iog88nd"
May 11 13:29:52.421: INFO: Waiting up to 5m0s for PersistentVolume pvc-b08f9547-0df7-4d3b-8669-887f2463f7fe to get deleted
May 11 13:29:52.657: INFO: PersistentVolume pvc-b08f9547-0df7-4d3b-8669-887f2463f7fe found and phase=Bound (235.832287ms)
... skipping 7 lines ...

• [SLOW TEST:18.007 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (filesystem volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail to use a volume in a pod with mismatched mode [Slow]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:292
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (filesystem volmode)] volumeMode should fail to use a volume in a pod with mismatched mode [Slow]","total":-1,"completed":1,"skipped":8,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (default fs)] provisioning
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (default fs)] provisioning
... skipping 25 lines ...

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/provisioning.go:182
------------------------------
SSSSSS
------------------------------
External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] volumeMode 
  should fail to use a volume in a pod with mismatched mode [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:292

[BeforeEach] [Testpattern: Dynamic PV (block volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (block volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:174
STEP: Creating a kubernetes client
May 11 13:29:40.576: INFO: >>> kubeConfig: /root/.kube/config
STEP: Building a namespace api object, basename volumemode
STEP: Waiting for a default service account to be provisioned in namespace
[It] should fail to use a volume in a pod with mismatched mode [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:292
May 11 13:29:40.621: INFO: Creating resource for dynamic PV
May 11 13:29:40.621: INFO: Using claimSize:1Mi, test suite supported size:{ 1Mi}, driver(hostpath.csi.k8s.io) supported size:{ 1Mi} 
STEP: creating a StorageClass volumemode-6614-e2e-scs78g5
STEP: creating a claim
May 11 13:29:40.631: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iot44v5] to have phase Bound
May 11 13:29:40.636: INFO: PersistentVolumeClaim hostpath.csi.k8s.iot44v5 found but phase is Pending instead of Bound.
May 11 13:29:42.640: INFO: PersistentVolumeClaim hostpath.csi.k8s.iot44v5 found and phase=Bound (2.009075354s)
STEP: Creating pod
STEP: Waiting for the pod to fail
May 11 13:29:50.671: INFO: Deleting pod "pod-153d9b39-df7b-43ef-ba41-f039aca37911" in namespace "volumemode-6614"
May 11 13:29:50.678: INFO: Wait up to 5m0s for pod "pod-153d9b39-df7b-43ef-ba41-f039aca37911" to be fully deleted
STEP: Deleting pvc
May 11 13:30:02.685: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.iot44v5"
May 11 13:30:02.691: INFO: Waiting up to 5m0s for PersistentVolume pvc-e907d1b0-8d3a-4a64-b9be-f4db717b2c28 to get deleted
May 11 13:30:02.700: INFO: PersistentVolume pvc-e907d1b0-8d3a-4a64-b9be-f4db717b2c28 found and phase=Bound (9.174678ms)
... skipping 7 lines ...

• [SLOW TEST:27.140 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail to use a volume in a pod with mismatched mode [Slow]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:292
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] volumeMode should fail to use a volume in a pod with mismatched mode [Slow]","total":-1,"completed":1,"skipped":286,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (ntfs)][sig-windows] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:07.858: INFO: Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping
... skipping 3 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (ntfs)][sig-windows] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath with backstepping is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:275

    Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:178
------------------------------
... skipping 18 lines ...

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:247
------------------------------
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath 
  should fail if subpath directory is outside the volume [Slow][LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:237

[BeforeEach] [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:174
STEP: Creating a kubernetes client
May 11 13:29:40.181: INFO: >>> kubeConfig: /root/.kube/config
STEP: Building a namespace api object, basename provisioning
May 11 13:29:40.352: INFO: No PodSecurityPolicies found; assuming PodSecurityPolicy is disabled.
STEP: Waiting for a default service account to be provisioned in namespace
[It] should fail if subpath directory is outside the volume [Slow][LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:237
May 11 13:29:40.363: INFO: Creating resource for dynamic PV
May 11 13:29:40.363: INFO: Using claimSize:1Mi, test suite supported size:{ 1Mi}, driver(hostpath.csi.k8s.io) supported size:{ 1Mi} 
STEP: creating a StorageClass provisioning-4922-e2e-scmt7pv
STEP: creating a claim
May 11 13:29:40.386: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:29:40.419: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iokf2kc] to have phase Bound
May 11 13:29:40.439: INFO: PersistentVolumeClaim hostpath.csi.k8s.iokf2kc found but phase is Pending instead of Bound.
May 11 13:29:42.469: INFO: PersistentVolumeClaim hostpath.csi.k8s.iokf2kc found and phase=Bound (2.049326768s)
STEP: Creating pod pod-subpath-test-dynamicpv-lzfb
STEP: Checking for subpath error in container status
May 11 13:30:08.494: INFO: Deleting pod "pod-subpath-test-dynamicpv-lzfb" in namespace "provisioning-4922"
May 11 13:30:08.499: INFO: Wait up to 5m0s for pod "pod-subpath-test-dynamicpv-lzfb" to be fully deleted
STEP: Deleting pod
May 11 13:30:14.506: INFO: Deleting pod "pod-subpath-test-dynamicpv-lzfb" in namespace "provisioning-4922"
STEP: Deleting pvc
May 11 13:30:14.509: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.iokf2kc"
... skipping 9 lines ...

• [SLOW TEST:39.356 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath directory is outside the volume [Slow][LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:237
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should fail if subpath directory is outside the volume [Slow][LinuxOnly]","total":-1,"completed":1,"skipped":141,"failed":0}

SSSSSSS
------------------------------
[BeforeEach] [Testpattern: Inline-volume (default fs)] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:19.553: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "InlineVolume" - skipping
... skipping 83 lines ...
[BeforeEach] [Testpattern: Dynamic PV (immediate binding)] topology
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:174
STEP: Creating a kubernetes client
May 11 13:30:19.708: INFO: >>> kubeConfig: /root/.kube/config
STEP: Building a namespace api object, basename topology
STEP: Waiting for a default service account to be provisioned in namespace
[It] should fail to schedule a pod which has topologies that conflict with AllowedTopologies
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/topology.go:192
May 11 13:30:19.744: INFO: Driver didn't provide topology keys -- skipping
[AfterEach] [Testpattern: Dynamic PV (immediate binding)] topology
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:175
May 11 13:30:19.745: INFO: Waiting up to 3m0s for all (but 0) nodes to be ready
STEP: Destroying namespace "topology-8493" for this suite.


S [SKIPPING] [0.046 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (immediate binding)] topology
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail to schedule a pod which has topologies that conflict with AllowedTopologies [It]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/topology.go:192

    Driver didn't provide topology keys -- skipping

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/topology.go:124
------------------------------
... skipping 118 lines ...
May 11 13:29:57.817: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:29:57.826: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.io69n5r] to have phase Bound
May 11 13:29:57.829: INFO: PersistentVolumeClaim hostpath.csi.k8s.io69n5r found but phase is Pending instead of Bound.
May 11 13:30:00.022: INFO: PersistentVolumeClaim hostpath.csi.k8s.io69n5r found and phase=Bound (2.195721916s)
STEP: Creating pod pod-subpath-test-dynamicpv-cdbm
STEP: Creating a pod to test subpath
May 11 13:30:00.033: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-cdbm" in namespace "provisioning-4013" to be "Succeeded or Failed"
May 11 13:30:00.064: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Pending", Reason="", readiness=false. Elapsed: 30.117851ms
May 11 13:30:02.067: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Pending", Reason="", readiness=false. Elapsed: 2.033908101s
May 11 13:30:04.072: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Pending", Reason="", readiness=false. Elapsed: 4.038154044s
May 11 13:30:06.093: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Pending", Reason="", readiness=false. Elapsed: 6.059380711s
May 11 13:30:08.098: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Pending", Reason="", readiness=false. Elapsed: 8.064195551s
May 11 13:30:10.101: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Pending", Reason="", readiness=false. Elapsed: 10.067714507s
May 11 13:30:12.129: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Pending", Reason="", readiness=false. Elapsed: 12.095985927s
May 11 13:30:14.133: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Pending", Reason="", readiness=false. Elapsed: 14.099662426s
May 11 13:30:16.137: INFO: Pod "pod-subpath-test-dynamicpv-cdbm": Phase="Succeeded", Reason="", readiness=false. Elapsed: 16.103222906s
STEP: Saw pod success
May 11 13:30:16.137: INFO: Pod "pod-subpath-test-dynamicpv-cdbm" satisfied condition "Succeeded or Failed"
May 11 13:30:16.140: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-cdbm container test-container-subpath-dynamicpv-cdbm: <nil>
STEP: delete the pod
May 11 13:30:16.164: INFO: Waiting for pod pod-subpath-test-dynamicpv-cdbm to disappear
May 11 13:30:16.172: INFO: Pod pod-subpath-test-dynamicpv-cdbm no longer exists
STEP: Deleting pod pod-subpath-test-dynamicpv-cdbm
May 11 13:30:16.172: INFO: Deleting pod "pod-subpath-test-dynamicpv-cdbm" in namespace "provisioning-4013"
... skipping 16 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support readOnly file specified in the volumeMount [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:376
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support readOnly file specified in the volumeMount [LinuxOnly]","total":-1,"completed":2,"skipped":40,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Inline-volume (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:21.648: INFO: Driver supports dynamic provisioning, skipping InlineVolume pattern
... skipping 3 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Inline-volume (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if non-existent subpath is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:264

    Driver supports dynamic provisioning, skipping InlineVolume pattern

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:833
------------------------------
... skipping 84 lines ...
May 11 13:29:40.323: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:29:40.361: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iot254f] to have phase Bound
May 11 13:29:40.367: INFO: PersistentVolumeClaim hostpath.csi.k8s.iot254f found but phase is Pending instead of Bound.
May 11 13:29:42.372: INFO: PersistentVolumeClaim hostpath.csi.k8s.iot254f found and phase=Bound (2.010981075s)
STEP: Creating pod pod-subpath-test-dynamicpv-8hxh
STEP: Creating a pod to test atomic-volume-subpath
May 11 13:29:42.408: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-8hxh" in namespace "provisioning-9936" to be "Succeeded or Failed"
May 11 13:29:42.428: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Pending", Reason="", readiness=false. Elapsed: 20.038198ms
May 11 13:29:44.432: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Pending", Reason="", readiness=false. Elapsed: 2.024188972s
May 11 13:29:46.675: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Pending", Reason="", readiness=false. Elapsed: 4.266554685s
May 11 13:29:48.678: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Pending", Reason="", readiness=false. Elapsed: 6.269918077s
May 11 13:29:50.684: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Pending", Reason="", readiness=false. Elapsed: 8.275699297s
May 11 13:29:52.899: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Pending", Reason="", readiness=false. Elapsed: 10.491031216s
... skipping 10 lines ...
May 11 13:30:14.944: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Running", Reason="", readiness=true. Elapsed: 32.535541457s
May 11 13:30:16.948: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Running", Reason="", readiness=true. Elapsed: 34.540048553s
May 11 13:30:18.952: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Running", Reason="", readiness=true. Elapsed: 36.543962449s
May 11 13:30:20.957: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Running", Reason="", readiness=true. Elapsed: 38.549046141s
May 11 13:30:22.961: INFO: Pod "pod-subpath-test-dynamicpv-8hxh": Phase="Succeeded", Reason="", readiness=false. Elapsed: 40.552979047s
STEP: Saw pod success
May 11 13:30:22.961: INFO: Pod "pod-subpath-test-dynamicpv-8hxh" satisfied condition "Succeeded or Failed"
May 11 13:30:22.965: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-8hxh container test-container-subpath-dynamicpv-8hxh: <nil>
STEP: delete the pod
May 11 13:30:23.011: INFO: Waiting for pod pod-subpath-test-dynamicpv-8hxh to disappear
May 11 13:30:23.015: INFO: Pod pod-subpath-test-dynamicpv-8hxh no longer exists
STEP: Deleting pod pod-subpath-test-dynamicpv-8hxh
May 11 13:30:23.015: INFO: Deleting pod "pod-subpath-test-dynamicpv-8hxh" in namespace "provisioning-9936"
... skipping 16 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support file as subpath [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:227
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support file as subpath [LinuxOnly]","total":-1,"completed":1,"skipped":28,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Inline-volume (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:28.113: INFO: Driver supports dynamic provisioning, skipping InlineVolume pattern
... skipping 3 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.002 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Inline-volume (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath file is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:253

    Driver supports dynamic provisioning, skipping InlineVolume pattern

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:833
------------------------------
... skipping 75 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should not mount / map unused volumes in a pod [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:347
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] volumeMode should not mount / map unused volumes in a pod [LinuxOnly]","total":-1,"completed":1,"skipped":6,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (default fs)] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:28.567: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "PreprovisionedPV" - skipping
... skipping 235 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should concurrently access the single volume from pods on the same node [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:308
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow] should concurrently access the single volume from pods on the same node [LinuxOnly]","total":-1,"completed":1,"skipped":241,"failed":0}

SSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:38.153: INFO: Driver supports dynamic provisioning, skipping PreprovisionedPV pattern
... skipping 3 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.003 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Pre-provisioned PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath file is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:253

    Driver supports dynamic provisioning, skipping PreprovisionedPV pattern

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:833
------------------------------
... skipping 53 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (filesystem volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should not mount / map unused volumes in a pod [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:347
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (filesystem volmode)] volumeMode should not mount / map unused volumes in a pod [LinuxOnly]","total":-1,"completed":2,"skipped":438,"failed":0}

SSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Inline-volume (ext4)] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:47.686: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "InlineVolume" - skipping
... skipping 103 lines ...
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should concurrently access the single read-only volume from pods on the same node
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:333
------------------------------
S
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] multiVolume [Slow] should concurrently access the single read-only volume from pods on the same node","total":-1,"completed":2,"skipped":477,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (filesystem volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:47.920: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "PreprovisionedPV" - skipping
... skipping 99 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (ntfs)][sig-windows] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath directory is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:237

    Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:178
------------------------------
... skipping 29 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (ntfs)][sig-windows] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if non-existent subpath is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:264

    Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:178
------------------------------
... skipping 74 lines ...
May 11 13:30:29.144: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:30:29.152: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iox2gbz] to have phase Bound
May 11 13:30:29.162: INFO: PersistentVolumeClaim hostpath.csi.k8s.iox2gbz found but phase is Pending instead of Bound.
May 11 13:30:31.165: INFO: PersistentVolumeClaim hostpath.csi.k8s.iox2gbz found and phase=Bound (2.013420711s)
STEP: Creating pod pod-subpath-test-dynamicpv-d6t5
STEP: Creating a pod to test subpath
May 11 13:30:31.175: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-d6t5" in namespace "provisioning-1168" to be "Succeeded or Failed"
May 11 13:30:31.179: INFO: Pod "pod-subpath-test-dynamicpv-d6t5": Phase="Pending", Reason="", readiness=false. Elapsed: 4.170924ms
May 11 13:30:33.208: INFO: Pod "pod-subpath-test-dynamicpv-d6t5": Phase="Pending", Reason="", readiness=false. Elapsed: 2.033068993s
May 11 13:30:35.211: INFO: Pod "pod-subpath-test-dynamicpv-d6t5": Phase="Pending", Reason="", readiness=false. Elapsed: 4.036155193s
May 11 13:30:37.215: INFO: Pod "pod-subpath-test-dynamicpv-d6t5": Phase="Pending", Reason="", readiness=false. Elapsed: 6.040105429s
May 11 13:30:39.221: INFO: Pod "pod-subpath-test-dynamicpv-d6t5": Phase="Pending", Reason="", readiness=false. Elapsed: 8.045394253s
May 11 13:30:41.224: INFO: Pod "pod-subpath-test-dynamicpv-d6t5": Phase="Pending", Reason="", readiness=false. Elapsed: 10.048723157s
May 11 13:30:43.232: INFO: Pod "pod-subpath-test-dynamicpv-d6t5": Phase="Succeeded", Reason="", readiness=false. Elapsed: 12.056469416s
STEP: Saw pod success
May 11 13:30:43.232: INFO: Pod "pod-subpath-test-dynamicpv-d6t5" satisfied condition "Succeeded or Failed"
May 11 13:30:43.237: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-d6t5 container test-container-subpath-dynamicpv-d6t5: <nil>
STEP: delete the pod
May 11 13:30:43.255: INFO: Waiting for pod pod-subpath-test-dynamicpv-d6t5 to disappear
May 11 13:30:43.257: INFO: Pod pod-subpath-test-dynamicpv-d6t5 no longer exists
STEP: Deleting pod pod-subpath-test-dynamicpv-d6t5
May 11 13:30:43.258: INFO: Deleting pod "pod-subpath-test-dynamicpv-d6t5" in namespace "provisioning-1168"
... skipping 18 lines ...
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support existing single file [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:216
------------------------------
S
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support existing single file [LinuxOnly]","total":-1,"completed":2,"skipped":370,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (filesystem volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:48.347: INFO: Driver supports dynamic provisioning, skipping PreprovisionedPV pattern
... skipping 45 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Pre-provisioned PV (filesystem volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail to use a volume in a pod with mismatched mode [Slow] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:292

    Driver "hostpath.csi.k8s.io" does not support volume type "PreprovisionedPV" - skipping

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:247
------------------------------
... skipping 8 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Pre-provisioned PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath directory is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:237

    Driver supports dynamic provisioning, skipping PreprovisionedPV pattern

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:833
------------------------------
... skipping 63 lines ...
STEP: creating a claim
May 11 13:30:28.184: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:30:28.189: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.io9l9gz] to have phase Bound
May 11 13:30:28.194: INFO: PersistentVolumeClaim hostpath.csi.k8s.io9l9gz found but phase is Pending instead of Bound.
May 11 13:30:30.197: INFO: PersistentVolumeClaim hostpath.csi.k8s.io9l9gz found and phase=Bound (2.00760922s)
STEP: Creating pod to format volume volume-prep-provisioning-2218
May 11 13:30:30.207: INFO: Waiting up to 5m0s for pod "volume-prep-provisioning-2218" in namespace "provisioning-2218" to be "Succeeded or Failed"
May 11 13:30:30.212: INFO: Pod "volume-prep-provisioning-2218": Phase="Pending", Reason="", readiness=false. Elapsed: 4.759036ms
May 11 13:30:32.216: INFO: Pod "volume-prep-provisioning-2218": Phase="Pending", Reason="", readiness=false. Elapsed: 2.00839083s
May 11 13:30:34.219: INFO: Pod "volume-prep-provisioning-2218": Phase="Pending", Reason="", readiness=false. Elapsed: 4.011685962s
May 11 13:30:36.223: INFO: Pod "volume-prep-provisioning-2218": Phase="Pending", Reason="", readiness=false. Elapsed: 6.015745507s
May 11 13:30:38.230: INFO: Pod "volume-prep-provisioning-2218": Phase="Pending", Reason="", readiness=false. Elapsed: 8.022243299s
May 11 13:30:40.233: INFO: Pod "volume-prep-provisioning-2218": Phase="Succeeded", Reason="", readiness=false. Elapsed: 10.02597811s
STEP: Saw pod success
May 11 13:30:40.233: INFO: Pod "volume-prep-provisioning-2218" satisfied condition "Succeeded or Failed"
May 11 13:30:40.233: INFO: Deleting pod "volume-prep-provisioning-2218" in namespace "provisioning-2218"
May 11 13:30:40.242: INFO: Wait up to 5m0s for pod "volume-prep-provisioning-2218" to be fully deleted
STEP: Creating pod pod-subpath-test-dynamicpv-znv8
STEP: Checking for subpath error in container status
May 11 13:30:50.257: INFO: Deleting pod "pod-subpath-test-dynamicpv-znv8" in namespace "provisioning-2218"
May 11 13:30:50.274: INFO: Wait up to 5m0s for pod "pod-subpath-test-dynamicpv-znv8" to be fully deleted
STEP: Deleting pod
May 11 13:30:50.276: INFO: Deleting pod "pod-subpath-test-dynamicpv-znv8" in namespace "provisioning-2218"
STEP: Deleting pvc
May 11 13:30:50.279: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.io9l9gz"
... skipping 12 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should verify container cannot write to subpath readonly volumes [Slow]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:419
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should verify container cannot write to subpath readonly volumes [Slow]","total":-1,"completed":2,"skipped":84,"failed":0}
[BeforeEach] [Testpattern: CSI Ephemeral-volume (default fs)] ephemeral
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:30:55.308: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "CSIInlineVolume" - skipping
[AfterEach] [Testpattern: CSI Ephemeral-volume (default fs)] ephemeral
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:175

... skipping 97 lines ...
STEP: creating a claim
May 11 13:30:22.003: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iornc4s] to have phase Bound
May 11 13:30:22.011: INFO: PersistentVolumeClaim hostpath.csi.k8s.iornc4s found but phase is Pending instead of Bound.
May 11 13:30:24.016: INFO: PersistentVolumeClaim hostpath.csi.k8s.iornc4s found and phase=Bound (2.01249228s)
STEP: Expanding non-expandable pvc
May 11 13:30:24.022: INFO: currentPvcSize {{1073741824 0} {<nil>} 1Gi BinarySI}, newSize {{2147483648 0} {<nil>}  BinarySI}
May 11 13:30:24.031: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:26.041: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:28.041: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:30.039: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:32.040: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:34.039: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:36.040: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:38.039: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:40.041: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:42.038: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:44.040: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:46.038: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:48.040: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:50.039: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:52.045: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:54.038: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:30:54.046: INFO: Error updating pvc hostpath.csi.k8s.iornc4s: persistentvolumeclaims "hostpath.csi.k8s.iornc4s" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
STEP: Deleting pvc
May 11 13:30:54.046: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.iornc4s"
May 11 13:30:54.051: INFO: Waiting up to 5m0s for PersistentVolume pvc-b080d133-a9a7-486c-b718-d7c4bbd55443 to get deleted
May 11 13:30:54.060: INFO: PersistentVolume pvc-b080d133-a9a7-486c-b718-d7c4bbd55443 found and phase=Bound (8.408057ms)
May 11 13:30:59.063: INFO: PersistentVolume pvc-b080d133-a9a7-486c-b718-d7c4bbd55443 was removed
STEP: Deleting sc
... skipping 8 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)] volume-expand
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should not allow expansion of pvcs without AllowVolumeExpansion property
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:154
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] volume-expand should not allow expansion of pvcs without AllowVolumeExpansion property","total":-1,"completed":3,"skipped":243,"failed":0}

SSSSSSSSSSSSSSS
------------------------------
External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath 
  should support existing directory
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:202
... skipping 15 lines ...
May 11 13:30:48.922: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:30:48.938: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iodmgzr] to have phase Bound
May 11 13:30:48.949: INFO: PersistentVolumeClaim hostpath.csi.k8s.iodmgzr found but phase is Pending instead of Bound.
May 11 13:30:50.957: INFO: PersistentVolumeClaim hostpath.csi.k8s.iodmgzr found and phase=Bound (2.019152803s)
STEP: Creating pod pod-subpath-test-dynamicpv-6lr8
STEP: Creating a pod to test subpath
May 11 13:30:50.968: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-6lr8" in namespace "provisioning-1366" to be "Succeeded or Failed"
May 11 13:30:50.973: INFO: Pod "pod-subpath-test-dynamicpv-6lr8": Phase="Pending", Reason="", readiness=false. Elapsed: 2.92187ms
May 11 13:30:52.981: INFO: Pod "pod-subpath-test-dynamicpv-6lr8": Phase="Pending", Reason="", readiness=false. Elapsed: 2.011175204s
May 11 13:30:54.985: INFO: Pod "pod-subpath-test-dynamicpv-6lr8": Phase="Pending", Reason="", readiness=false. Elapsed: 4.01476029s
May 11 13:30:56.989: INFO: Pod "pod-subpath-test-dynamicpv-6lr8": Phase="Pending", Reason="", readiness=false. Elapsed: 6.018844348s
May 11 13:30:58.997: INFO: Pod "pod-subpath-test-dynamicpv-6lr8": Phase="Pending", Reason="", readiness=false. Elapsed: 8.026563758s
May 11 13:31:01.000: INFO: Pod "pod-subpath-test-dynamicpv-6lr8": Phase="Pending", Reason="", readiness=false. Elapsed: 10.030317629s
May 11 13:31:03.004: INFO: Pod "pod-subpath-test-dynamicpv-6lr8": Phase="Succeeded", Reason="", readiness=false. Elapsed: 12.033990338s
STEP: Saw pod success
May 11 13:31:03.004: INFO: Pod "pod-subpath-test-dynamicpv-6lr8" satisfied condition "Succeeded or Failed"
May 11 13:31:03.007: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-6lr8 container test-container-volume-dynamicpv-6lr8: <nil>
STEP: delete the pod
May 11 13:31:03.022: INFO: Waiting for pod pod-subpath-test-dynamicpv-6lr8 to disappear
May 11 13:31:03.025: INFO: Pod pod-subpath-test-dynamicpv-6lr8 no longer exists
STEP: Deleting pod pod-subpath-test-dynamicpv-6lr8
May 11 13:31:03.025: INFO: Deleting pod "pod-subpath-test-dynamicpv-6lr8" in namespace "provisioning-1366"
... skipping 16 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support existing directory
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:202
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support existing directory","total":-1,"completed":3,"skipped":536,"failed":0}

SSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (ext4)] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:31:08.089: INFO: Driver hostpath.csi.k8s.io doesn't support ext4 -- skipping
... skipping 24 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Inline-volume (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath with backstepping is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:275

    Driver supports dynamic provisioning, skipping InlineVolume pattern

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:833
------------------------------
... skipping 49 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)(allowExpansion)] volume-expand
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should resize volume when PVC is edited while pod is using it
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:241
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)(allowExpansion)] volume-expand should resize volume when PVC is edited while pod is using it","total":-1,"completed":2,"skipped":310,"failed":0}

SSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (block volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:31:11.427: INFO: Driver supports dynamic provisioning, skipping PreprovisionedPV pattern
... skipping 86 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)(allowExpansion)] volume-expand
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should resize volume when PVC is edited while pod is using it
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:241
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)(allowExpansion)] volume-expand should resize volume when PVC is edited while pod is using it","total":-1,"completed":1,"skipped":24,"failed":0}

SSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (delayed binding)] topology
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (delayed binding)] topology
... skipping 48 lines ...
May 11 13:31:08.168: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:31:08.174: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.ioswlqz] to have phase Bound
May 11 13:31:08.178: INFO: PersistentVolumeClaim hostpath.csi.k8s.ioswlqz found but phase is Pending instead of Bound.
May 11 13:31:10.181: INFO: PersistentVolumeClaim hostpath.csi.k8s.ioswlqz found and phase=Bound (2.006593412s)
STEP: Creating pod pod-subpath-test-dynamicpv-8bwj
STEP: Creating a pod to test subpath
May 11 13:31:10.190: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-8bwj" in namespace "provisioning-8890" to be "Succeeded or Failed"
May 11 13:31:10.194: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 3.312524ms
May 11 13:31:12.197: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 2.006957632s
May 11 13:31:14.202: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 4.01156658s
May 11 13:31:16.206: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 6.015527182s
May 11 13:31:18.211: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 8.020528031s
May 11 13:31:20.216: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 10.025163291s
May 11 13:31:22.222: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 12.03193521s
May 11 13:31:24.229: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 14.03912733s
May 11 13:31:26.236: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Pending", Reason="", readiness=false. Elapsed: 16.046057003s
May 11 13:31:28.348: INFO: Pod "pod-subpath-test-dynamicpv-8bwj": Phase="Succeeded", Reason="", readiness=false. Elapsed: 18.157977314s
STEP: Saw pod success
May 11 13:31:28.348: INFO: Pod "pod-subpath-test-dynamicpv-8bwj" satisfied condition "Succeeded or Failed"
May 11 13:31:28.352: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-8bwj container test-container-volume-dynamicpv-8bwj: <nil>
STEP: delete the pod
May 11 13:31:28.812: INFO: Waiting for pod pod-subpath-test-dynamicpv-8bwj to disappear
May 11 13:31:28.848: INFO: Pod pod-subpath-test-dynamicpv-8bwj no longer exists
STEP: Deleting pod pod-subpath-test-dynamicpv-8bwj
May 11 13:31:28.849: INFO: Deleting pod "pod-subpath-test-dynamicpv-8bwj" in namespace "provisioning-8890"
... skipping 16 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support non-existent path
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:191
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support non-existent path","total":-1,"completed":4,"skipped":583,"failed":0}

SSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (ntfs)][sig-windows] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:31:33.906: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "PreprovisionedPV" - skipping
... skipping 144 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should access to two volumes with different volume mode and retain data across pod recreation on the same node [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:210
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] multiVolume [Slow] should access to two volumes with different volume mode and retain data across pod recreation on the same node [LinuxOnly]","total":-1,"completed":3,"skipped":764,"failed":0}

SSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (filesystem volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:31:48.507: INFO: Driver supports dynamic provisioning, skipping PreprovisionedPV pattern
... skipping 62 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] volumeIO
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should write files of various sizes, verify size, validate content [Slow][LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_io.go:144
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] volumeIO should write files of various sizes, verify size, validate content [Slow][LinuxOnly]","total":-1,"completed":4,"skipped":258,"failed":0}

SSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (ntfs)][sig-windows] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:31:52.578: INFO: Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping
... skipping 240 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)(allowExpansion)] volume-expand
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    Verify if offline PVC expansion works
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:169
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)(allowExpansion)] volume-expand Verify if offline PVC expansion works","total":-1,"completed":2,"skipped":73,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (ntfs)][sig-windows] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:32:04.941: INFO: Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping
... skipping 144 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should access to two volumes with the same volume mode and retain data across pod recreation on the same node [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:130
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow] should access to two volumes with the same volume mode and retain data across pod recreation on the same node [LinuxOnly]","total":-1,"completed":3,"skipped":358,"failed":0}

SSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Inline-volume (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:32:08.456: INFO: Driver supports dynamic provisioning, skipping InlineVolume pattern
... skipping 24 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Pre-provisioned PV (block volmode)] volumeMode
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail to use a volume in a pod with mismatched mode [Slow] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumemode.go:292

    Driver "hostpath.csi.k8s.io" does not support volume type "PreprovisionedPV" - skipping

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:247
------------------------------
... skipping 41 lines ...
May 11 13:31:48.699: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:31:48.706: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iotk8l5] to have phase Bound
May 11 13:31:48.712: INFO: PersistentVolumeClaim hostpath.csi.k8s.iotk8l5 found but phase is Pending instead of Bound.
May 11 13:31:50.716: INFO: PersistentVolumeClaim hostpath.csi.k8s.iotk8l5 found and phase=Bound (2.009954686s)
STEP: Creating pod pod-subpath-test-dynamicpv-xrlv
STEP: Creating a pod to test subpath
May 11 13:31:50.726: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-xrlv" in namespace "provisioning-1450" to be "Succeeded or Failed"
May 11 13:31:50.736: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 8.799327ms
May 11 13:31:52.740: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 2.013136015s
May 11 13:31:54.745: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 4.017924004s
May 11 13:31:56.748: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 6.021367856s
May 11 13:31:58.973: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 8.246703985s
May 11 13:32:00.977: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 10.250708171s
May 11 13:32:02.982: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 12.254812536s
May 11 13:32:04.985: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Succeeded", Reason="", readiness=false. Elapsed: 14.257872938s
STEP: Saw pod success
May 11 13:32:04.985: INFO: Pod "pod-subpath-test-dynamicpv-xrlv" satisfied condition "Succeeded or Failed"
May 11 13:32:04.989: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-xrlv container test-container-subpath-dynamicpv-xrlv: <nil>
STEP: delete the pod
May 11 13:32:05.012: INFO: Waiting for pod pod-subpath-test-dynamicpv-xrlv to disappear
May 11 13:32:05.020: INFO: Pod pod-subpath-test-dynamicpv-xrlv no longer exists
STEP: Deleting pod pod-subpath-test-dynamicpv-xrlv
May 11 13:32:05.020: INFO: Deleting pod "pod-subpath-test-dynamicpv-xrlv" in namespace "provisioning-1450"
STEP: Creating pod pod-subpath-test-dynamicpv-xrlv
STEP: Creating a pod to test subpath
May 11 13:32:05.028: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-xrlv" in namespace "provisioning-1450" to be "Succeeded or Failed"
May 11 13:32:05.030: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 2.59784ms
May 11 13:32:07.035: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Pending", Reason="", readiness=false. Elapsed: 2.007061058s
May 11 13:32:09.038: INFO: Pod "pod-subpath-test-dynamicpv-xrlv": Phase="Succeeded", Reason="", readiness=false. Elapsed: 4.010570475s
STEP: Saw pod success
May 11 13:32:09.038: INFO: Pod "pod-subpath-test-dynamicpv-xrlv" satisfied condition "Succeeded or Failed"
May 11 13:32:09.042: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-xrlv container test-container-subpath-dynamicpv-xrlv: <nil>
STEP: delete the pod
May 11 13:32:09.062: INFO: Waiting for pod pod-subpath-test-dynamicpv-xrlv to disappear
May 11 13:32:09.067: INFO: Pod pod-subpath-test-dynamicpv-xrlv no longer exists
STEP: Deleting pod pod-subpath-test-dynamicpv-xrlv
May 11 13:32:09.067: INFO: Deleting pod "pod-subpath-test-dynamicpv-xrlv" in namespace "provisioning-1450"
... skipping 16 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support existing directories when readOnly specified in the volumeSource
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:391
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support existing directories when readOnly specified in the volumeSource","total":-1,"completed":4,"skipped":827,"failed":0}

SSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (default fs)] provisioning
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (default fs)] provisioning
... skipping 36 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Inline-volume (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath directory is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:237

    Driver supports dynamic provisioning, skipping InlineVolume pattern

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:833
------------------------------
... skipping 138 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should store data
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:151
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] volumes should store data","total":-1,"completed":3,"skipped":189,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Inline-volume (ntfs)][sig-windows] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:32:17.756: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "InlineVolume" - skipping
... skipping 165 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should access to two volumes with the same volume mode and retain data across pod recreation on the same node [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:130
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] multiVolume [Slow] should access to two volumes with the same volume mode and retain data across pod recreation on the same node [LinuxOnly]","total":-1,"completed":5,"skipped":633,"failed":0}

SSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (block volmode)] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:32:35.128: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "PreprovisionedPV" - skipping
... skipping 24 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (ntfs)][sig-windows] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath file is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:253

    Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:178
------------------------------
... skipping 213 lines ...

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:247
------------------------------
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath 
  should fail if subpath with backstepping is outside the volume [Slow][LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:275

[BeforeEach] [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:174
STEP: Creating a kubernetes client
May 11 13:32:08.592: INFO: >>> kubeConfig: /root/.kube/config
STEP: Building a namespace api object, basename provisioning
STEP: Waiting for a default service account to be provisioned in namespace
[It] should fail if subpath with backstepping is outside the volume [Slow][LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:275
May 11 13:32:08.628: INFO: Creating resource for dynamic PV
May 11 13:32:08.628: INFO: Using claimSize:1Mi, test suite supported size:{ 1Mi}, driver(hostpath.csi.k8s.io) supported size:{ 1Mi} 
STEP: creating a StorageClass provisioning-23-e2e-scvgwvr
STEP: creating a claim
May 11 13:32:08.633: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:32:08.639: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iohhg8d] to have phase Bound
May 11 13:32:08.643: INFO: PersistentVolumeClaim hostpath.csi.k8s.iohhg8d found but phase is Pending instead of Bound.
May 11 13:32:10.650: INFO: PersistentVolumeClaim hostpath.csi.k8s.iohhg8d found and phase=Bound (2.010561351s)
STEP: Creating pod pod-subpath-test-dynamicpv-9vkh
STEP: Checking for subpath error in container status
May 11 13:32:24.672: INFO: Deleting pod "pod-subpath-test-dynamicpv-9vkh" in namespace "provisioning-23"
May 11 13:32:24.679: INFO: Wait up to 5m0s for pod "pod-subpath-test-dynamicpv-9vkh" to be fully deleted
STEP: Deleting pod
May 11 13:32:32.689: INFO: Deleting pod "pod-subpath-test-dynamicpv-9vkh" in namespace "provisioning-23"
STEP: Deleting pvc
May 11 13:32:32.698: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.iohhg8d"
... skipping 9 lines ...

• [SLOW TEST:29.197 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath with backstepping is outside the volume [Slow][LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:275
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should fail if subpath with backstepping is outside the volume [Slow][LinuxOnly]","total":-1,"completed":4,"skipped":471,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath 
  should fail if non-existent subpath is outside the volume [Slow][LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:264

[BeforeEach] [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:174
STEP: Creating a kubernetes client
May 11 13:32:17.913: INFO: >>> kubeConfig: /root/.kube/config
STEP: Building a namespace api object, basename provisioning
STEP: Waiting for a default service account to be provisioned in namespace
[It] should fail if non-existent subpath is outside the volume [Slow][LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:264
May 11 13:32:17.943: INFO: Creating resource for dynamic PV
May 11 13:32:17.944: INFO: Using claimSize:1Mi, test suite supported size:{ 1Mi}, driver(hostpath.csi.k8s.io) supported size:{ 1Mi} 
STEP: creating a StorageClass provisioning-6565-e2e-sc57bf4
STEP: creating a claim
May 11 13:32:17.947: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:32:17.952: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iolcr52] to have phase Bound
May 11 13:32:17.957: INFO: PersistentVolumeClaim hostpath.csi.k8s.iolcr52 found but phase is Pending instead of Bound.
May 11 13:32:19.960: INFO: PersistentVolumeClaim hostpath.csi.k8s.iolcr52 found and phase=Bound (2.007441981s)
STEP: Creating pod pod-subpath-test-dynamicpv-dpx9
STEP: Checking for subpath error in container status
May 11 13:32:31.976: INFO: Deleting pod "pod-subpath-test-dynamicpv-dpx9" in namespace "provisioning-6565"
May 11 13:32:31.986: INFO: Wait up to 5m0s for pod "pod-subpath-test-dynamicpv-dpx9" to be fully deleted
STEP: Deleting pod
May 11 13:32:41.996: INFO: Deleting pod "pod-subpath-test-dynamicpv-dpx9" in namespace "provisioning-6565"
STEP: Deleting pvc
May 11 13:32:42.001: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.iolcr52"
... skipping 9 lines ...

• [SLOW TEST:29.149 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if non-existent subpath is outside the volume [Slow][LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:264
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should fail if non-existent subpath is outside the volume [Slow][LinuxOnly]","total":-1,"completed":4,"skipped":339,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (ntfs)][sig-windows] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:32:47.140: INFO: Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping
... skipping 13 lines ...

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:178
------------------------------
SSSSSSSSSSSS
------------------------------
External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath 
  should fail if subpath file is outside the volume [Slow][LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:253

[BeforeEach] [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:174
STEP: Creating a kubernetes client
May 11 13:32:14.298: INFO: >>> kubeConfig: /root/.kube/config
STEP: Building a namespace api object, basename provisioning
STEP: Waiting for a default service account to be provisioned in namespace
[It] should fail if subpath file is outside the volume [Slow][LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:253
May 11 13:32:14.333: INFO: Creating resource for dynamic PV
May 11 13:32:14.333: INFO: Using claimSize:1Mi, test suite supported size:{ 1Mi}, driver(hostpath.csi.k8s.io) supported size:{ 1Mi} 
STEP: creating a StorageClass provisioning-1391-e2e-scqgrll
STEP: creating a claim
May 11 13:32:14.338: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:32:14.347: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iodvd97] to have phase Bound
May 11 13:32:14.350: INFO: PersistentVolumeClaim hostpath.csi.k8s.iodvd97 found but phase is Pending instead of Bound.
May 11 13:32:16.354: INFO: PersistentVolumeClaim hostpath.csi.k8s.iodvd97 found and phase=Bound (2.007454043s)
STEP: Creating pod pod-subpath-test-dynamicpv-nqml
STEP: Checking for subpath error in container status
May 11 13:32:36.375: INFO: Deleting pod "pod-subpath-test-dynamicpv-nqml" in namespace "provisioning-1391"
May 11 13:32:36.382: INFO: Wait up to 5m0s for pod "pod-subpath-test-dynamicpv-nqml" to be fully deleted
STEP: Deleting pod
May 11 13:32:42.396: INFO: Deleting pod "pod-subpath-test-dynamicpv-nqml" in namespace "provisioning-1391"
STEP: Deleting pvc
May 11 13:32:42.400: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.iodvd97"
... skipping 9 lines ...

• [SLOW TEST:33.350 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath file is outside the volume [Slow][LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:253
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should fail if subpath file is outside the volume [Slow][LinuxOnly]","total":-1,"completed":5,"skipped":898,"failed":0}

SSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
[BeforeEach] [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow]
... skipping 48 lines ...
May 11 13:32:49.690: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:32:49.704: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.ioj2xkh] to have phase Bound
May 11 13:32:49.707: INFO: PersistentVolumeClaim hostpath.csi.k8s.ioj2xkh found but phase is Pending instead of Bound.
May 11 13:32:51.710: INFO: PersistentVolumeClaim hostpath.csi.k8s.ioj2xkh found and phase=Bound (2.006132303s)
STEP: Creating pod pod-subpath-test-dynamicpv-6m2c
STEP: Creating a pod to test subpath
May 11 13:32:51.719: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-6m2c" in namespace "provisioning-4840" to be "Succeeded or Failed"
May 11 13:32:51.726: INFO: Pod "pod-subpath-test-dynamicpv-6m2c": Phase="Pending", Reason="", readiness=false. Elapsed: 5.940952ms
May 11 13:32:53.886: INFO: Pod "pod-subpath-test-dynamicpv-6m2c": Phase="Pending", Reason="", readiness=false. Elapsed: 2.16519339s
May 11 13:32:55.889: INFO: Pod "pod-subpath-test-dynamicpv-6m2c": Phase="Pending", Reason="", readiness=false. Elapsed: 4.169038502s
May 11 13:32:57.893: INFO: Pod "pod-subpath-test-dynamicpv-6m2c": Phase="Pending", Reason="", readiness=false. Elapsed: 6.172517081s
May 11 13:32:59.902: INFO: Pod "pod-subpath-test-dynamicpv-6m2c": Phase="Pending", Reason="", readiness=false. Elapsed: 8.181636755s
May 11 13:33:01.908: INFO: Pod "pod-subpath-test-dynamicpv-6m2c": Phase="Pending", Reason="", readiness=false. Elapsed: 10.187931814s
May 11 13:33:03.912: INFO: Pod "pod-subpath-test-dynamicpv-6m2c": Phase="Succeeded", Reason="", readiness=false. Elapsed: 12.191890394s
STEP: Saw pod success
May 11 13:33:03.912: INFO: Pod "pod-subpath-test-dynamicpv-6m2c" satisfied condition "Succeeded or Failed"
May 11 13:33:03.915: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-6m2c container test-container-subpath-dynamicpv-6m2c: <nil>
STEP: delete the pod
May 11 13:33:03.933: INFO: Waiting for pod pod-subpath-test-dynamicpv-6m2c to disappear
May 11 13:33:03.936: INFO: Pod pod-subpath-test-dynamicpv-6m2c no longer exists
STEP: Deleting pod pod-subpath-test-dynamicpv-6m2c
May 11 13:33:03.936: INFO: Deleting pod "pod-subpath-test-dynamicpv-6m2c" in namespace "provisioning-4840"
... skipping 16 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support readOnly directory specified in the volumeMount
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:361
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support readOnly directory specified in the volumeMount","total":-1,"completed":6,"skipped":991,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:33:09.020: INFO: Driver supports dynamic provisioning, skipping PreprovisionedPV pattern
... skipping 3 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Pre-provisioned PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if non-existent subpath is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:264

    Driver supports dynamic provisioning, skipping PreprovisionedPV pattern

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:833
------------------------------
... skipping 104 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support restarting containers using file as subpath [Slow][LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:332
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support restarting containers using file as subpath [Slow][LinuxOnly]","total":-1,"completed":3,"skipped":835,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (ntfs)][sig-windows] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:33:28.165: INFO: Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping
... skipping 75 lines ...
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    Verify if offline PVC expansion works
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:169
------------------------------
SS
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)(allowExpansion)] volume-expand Verify if offline PVC expansion works","total":-1,"completed":3,"skipped":129,"failed":0}

SSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Pre-provisioned PV (ext3)] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:33:28.301: INFO: Driver "hostpath.csi.k8s.io" does not support volume type "PreprovisionedPV" - skipping
... skipping 141 lines ...
May 11 13:33:09.213: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:33:09.219: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iompcpj] to have phase Bound
May 11 13:33:09.225: INFO: PersistentVolumeClaim hostpath.csi.k8s.iompcpj found but phase is Pending instead of Bound.
May 11 13:33:11.230: INFO: PersistentVolumeClaim hostpath.csi.k8s.iompcpj found and phase=Bound (2.010207515s)
STEP: Creating pod pod-subpath-test-dynamicpv-6rrc
STEP: Creating a pod to test multi_subpath
May 11 13:33:11.243: INFO: Waiting up to 5m0s for pod "pod-subpath-test-dynamicpv-6rrc" in namespace "provisioning-5772" to be "Succeeded or Failed"
May 11 13:33:11.256: INFO: Pod "pod-subpath-test-dynamicpv-6rrc": Phase="Pending", Reason="", readiness=false. Elapsed: 13.355454ms
May 11 13:33:13.262: INFO: Pod "pod-subpath-test-dynamicpv-6rrc": Phase="Pending", Reason="", readiness=false. Elapsed: 2.018926061s
May 11 13:33:15.266: INFO: Pod "pod-subpath-test-dynamicpv-6rrc": Phase="Pending", Reason="", readiness=false. Elapsed: 4.023217742s
May 11 13:33:17.270: INFO: Pod "pod-subpath-test-dynamicpv-6rrc": Phase="Pending", Reason="", readiness=false. Elapsed: 6.026539273s
May 11 13:33:19.273: INFO: Pod "pod-subpath-test-dynamicpv-6rrc": Phase="Pending", Reason="", readiness=false. Elapsed: 8.030251528s
May 11 13:33:21.277: INFO: Pod "pod-subpath-test-dynamicpv-6rrc": Phase="Pending", Reason="", readiness=false. Elapsed: 10.033840637s
May 11 13:33:23.281: INFO: Pod "pod-subpath-test-dynamicpv-6rrc": Phase="Succeeded", Reason="", readiness=false. Elapsed: 12.038350152s
STEP: Saw pod success
May 11 13:33:23.281: INFO: Pod "pod-subpath-test-dynamicpv-6rrc" satisfied condition "Succeeded or Failed"
May 11 13:33:23.284: INFO: Trying to get logs from node csi-prow-worker2 pod pod-subpath-test-dynamicpv-6rrc container test-container-subpath-dynamicpv-6rrc: <nil>
STEP: delete the pod
May 11 13:33:23.300: INFO: Waiting for pod pod-subpath-test-dynamicpv-6rrc to disappear
May 11 13:33:23.303: INFO: Pod pod-subpath-test-dynamicpv-6rrc no longer exists
STEP: Deleting pod
May 11 13:33:23.303: INFO: Deleting pod "pod-subpath-test-dynamicpv-6rrc" in namespace "provisioning-5772"
... skipping 14 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support creating multiple subpath from same volumes [Slow]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:291
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support creating multiple subpath from same volumes [Slow]","total":-1,"completed":7,"skipped":1123,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Dynamic PV (ntfs)][sig-windows] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:33:28.720: INFO: Driver hostpath.csi.k8s.io doesn't support ntfs -- skipping
... skipping 153 lines ...

S [SKIPPING] in Spec Setup (BeforeEach) [0.001 seconds]
External Storage [Driver: hostpath.csi.k8s.io]
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Pre-provisioned PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should fail if subpath with backstepping is outside the volume [Slow][LinuxOnly] [BeforeEach]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:275

    Driver supports dynamic provisioning, skipping PreprovisionedPV pattern

    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:833
------------------------------
... skipping 359 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should concurrently access the single volume from pods on the same node [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:308
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] multiVolume [Slow] should concurrently access the single volume from pods on the same node [LinuxOnly]","total":-1,"completed":5,"skipped":513,"failed":0}

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
------------------------------
[BeforeEach] [Testpattern: Inline-volume (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:130
May 11 13:33:38.264: INFO: Driver supports dynamic provisioning, skipping InlineVolume pattern
... skipping 133 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] volumes
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should store data
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:151
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] volumes should store data","total":-1,"completed":5,"skipped":412,"failed":0}
May 11 13:33:39.891: INFO: Running AfterSuite actions on all nodes


External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] volumes 
  should allow exec of files on the volume
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:192
... skipping 15 lines ...
May 11 13:33:28.877: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:33:28.887: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iogthqq] to have phase Bound
May 11 13:33:28.894: INFO: PersistentVolumeClaim hostpath.csi.k8s.iogthqq found but phase is Pending instead of Bound.
May 11 13:33:30.898: INFO: PersistentVolumeClaim hostpath.csi.k8s.iogthqq found and phase=Bound (2.010570424s)
STEP: Creating pod exec-volume-test-dynamicpv-xbcl
STEP: Creating a pod to test exec-volume-test
May 11 13:33:31.200: INFO: Waiting up to 5m0s for pod "exec-volume-test-dynamicpv-xbcl" in namespace "volume-5284" to be "Succeeded or Failed"
May 11 13:33:31.444: INFO: Pod "exec-volume-test-dynamicpv-xbcl": Phase="Pending", Reason="", readiness=false. Elapsed: 175.544485ms
May 11 13:33:33.452: INFO: Pod "exec-volume-test-dynamicpv-xbcl": Phase="Pending", Reason="", readiness=false. Elapsed: 2.183617688s
May 11 13:33:35.456: INFO: Pod "exec-volume-test-dynamicpv-xbcl": Phase="Pending", Reason="", readiness=false. Elapsed: 4.187413992s
May 11 13:33:37.459: INFO: Pod "exec-volume-test-dynamicpv-xbcl": Phase="Pending", Reason="", readiness=false. Elapsed: 6.191054238s
May 11 13:33:39.463: INFO: Pod "exec-volume-test-dynamicpv-xbcl": Phase="Pending", Reason="", readiness=false. Elapsed: 8.194590248s
May 11 13:33:41.466: INFO: Pod "exec-volume-test-dynamicpv-xbcl": Phase="Succeeded", Reason="", readiness=false. Elapsed: 10.197807816s
STEP: Saw pod success
May 11 13:33:41.466: INFO: Pod "exec-volume-test-dynamicpv-xbcl" satisfied condition "Succeeded or Failed"
May 11 13:33:41.469: INFO: Trying to get logs from node csi-prow-worker2 pod exec-volume-test-dynamicpv-xbcl container exec-container-dynamicpv-xbcl: <nil>
STEP: delete the pod
May 11 13:33:41.482: INFO: Waiting for pod exec-volume-test-dynamicpv-xbcl to disappear
May 11 13:33:41.485: INFO: Pod exec-volume-test-dynamicpv-xbcl no longer exists
STEP: Deleting pod exec-volume-test-dynamicpv-xbcl
May 11 13:33:41.485: INFO: Deleting pod "exec-volume-test-dynamicpv-xbcl" in namespace "volume-5284"
... skipping 85 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should concurrently access the single read-only volume from pods on the same node
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/multivolume.go:333
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (filesystem volmode)] multiVolume [Slow] should concurrently access the single read-only volume from pods on the same node","total":-1,"completed":5,"skipped":530,"failed":0}
May 11 13:33:57.718: INFO: Running AfterSuite actions on all nodes


External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath 
  should be able to unmount after the subpath directory is deleted [LinuxOnly]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:441
... skipping 42 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should be able to unmount after the subpath directory is deleted [LinuxOnly]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:441
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should be able to unmount after the subpath directory is deleted [LinuxOnly]","total":-1,"completed":4,"skipped":1052,"failed":0}
May 11 13:33:58.492: INFO: Running AfterSuite actions on all nodes


External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] volume-expand 
  should not allow expansion of pvcs without AllowVolumeExpansion property
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:154
... skipping 17 lines ...
May 11 13:33:29.829: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:33:29.837: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.io4l85x] to have phase Bound
May 11 13:33:29.842: INFO: PersistentVolumeClaim hostpath.csi.k8s.io4l85x found but phase is Pending instead of Bound.
May 11 13:33:31.846: INFO: PersistentVolumeClaim hostpath.csi.k8s.io4l85x found and phase=Bound (2.008950711s)
STEP: Expanding non-expandable pvc
May 11 13:33:31.851: INFO: currentPvcSize {{1073741824 0} {<nil>} 1Gi BinarySI}, newSize {{2147483648 0} {<nil>}  BinarySI}
May 11 13:33:31.861: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:33.871: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:35.870: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:37.869: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:39.871: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:41.870: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:43.874: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:45.870: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:47.869: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:49.869: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:51.870: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:53.870: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:55.869: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:57.869: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:33:59.872: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:34:01.870: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
May 11 13:34:01.877: INFO: Error updating pvc hostpath.csi.k8s.io4l85x: persistentvolumeclaims "hostpath.csi.k8s.io4l85x" is forbidden: only dynamically provisioned pvc can be resized and the storageclass that provisions the pvc must support resize
STEP: Deleting pvc
May 11 13:34:01.877: INFO: Deleting PersistentVolumeClaim "hostpath.csi.k8s.io4l85x"
May 11 13:34:01.881: INFO: Waiting up to 5m0s for PersistentVolume pvc-96c5506d-1c8a-4641-a974-b27a5fde7fa8 to get deleted
May 11 13:34:01.887: INFO: PersistentVolume pvc-96c5506d-1c8a-4641-a974-b27a5fde7fa8 found and phase=Bound (6.158892ms)
May 11 13:34:06.891: INFO: PersistentVolume pvc-96c5506d-1c8a-4641-a974-b27a5fde7fa8 was removed
STEP: Deleting sc
... skipping 8 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] volume-expand
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should not allow expansion of pvcs without AllowVolumeExpansion property
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volume_expand.go:154
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] volume-expand should not allow expansion of pvcs without AllowVolumeExpansion property","total":-1,"completed":4,"skipped":853,"failed":0}
May 11 13:34:06.910: INFO: Running AfterSuite actions on all nodes


External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath 
  should support restarting containers using directory as subpath [Slow]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:317
... skipping 56 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] subPath
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should support restarting containers using directory as subpath [Slow]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:317
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] subPath should support restarting containers using directory as subpath [Slow]","total":-1,"completed":6,"skipped":1205,"failed":0}
May 11 13:34:27.656: INFO: Running AfterSuite actions on all nodes


{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] volumes should allow exec of files on the volume","total":-1,"completed":8,"skipped":1177,"failed":0}
May 11 13:33:46.516: INFO: Running AfterSuite actions on all nodes
May 11 13:34:27.717: INFO: Running AfterSuite actions on node 1
May 11 13:34:27.717: INFO: Dumping logs locally to: /logs/artifacts
May 11 13:34:27.718: INFO: Error running cluster/log-dump/log-dump.sh: fork/exec ../../cluster/log-dump/log-dump.sh: no such file or directory


Ran 37 of 5870 Specs in 288.220 seconds
SUCCESS! -- 37 Passed | 0 Failed | 0 Pending | 5833 Skipped


Ginkgo ran 1 suite in 4m51.544101014s
Test Suite Passed
Tue May 11 13:34:27 UTC 2021 go1.16.4 /home/prow/go/src/k8s.io/kubernetes$ go run /home/prow/go/src/github.com/kubernetes-csi/external-provisioner/release-tools/filter-junit.go -t=External Storage -o /logs/artifacts/junit_parallel.xml /logs/artifacts/junit_01.xml /logs/artifacts/junit_02.xml /logs/artifacts/junit_03.xml /logs/artifacts/junit_04.xml /logs/artifacts/junit_05.xml /logs/artifacts/junit_06.xml /logs/artifacts/junit_07.xml
Tue May 11 13:34:28 UTC 2021 go1.16.4 /home/prow/go/src/github.com/onsi/ginkgo$ git fetch --depth=1 https://github.com/onsi/ginkgo v1.7.0
... skipping 199 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (block volmode)] provisioning
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should provision storage with snapshot data source [Feature:VolumeSnapshotDataSource]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/provisioning.go:198
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (block volmode)] provisioning should provision storage with snapshot data source [Feature:VolumeSnapshotDataSource]","total":-1,"completed":1,"skipped":280,"failed":0}
May 11 13:35:50.430: INFO: Running AfterSuite actions on all nodes


External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] provisioning 
  should provision storage with snapshot data source [Feature:VolumeSnapshotDataSource]
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/provisioning.go:198
... skipping 135 lines ...
/home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/external/external.go:169
  [Testpattern: Dynamic PV (default fs)] provisioning
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/base.go:129
    should provision storage with snapshot data source [Feature:VolumeSnapshotDataSource]
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/provisioning.go:198
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic PV (default fs)] provisioning should provision storage with snapshot data source [Feature:VolumeSnapshotDataSource]","total":-1,"completed":1,"skipped":944,"failed":0}
May 11 13:35:58.992: INFO: Running AfterSuite actions on all nodes


External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic Snapshot (delete policy)] snapshottable[Feature:VolumeSnapshotDataSource] volume snapshot controller  
  should check snapshot fields, check restore correctly works after modifying source data, check deletion
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
... skipping 17 lines ...
STEP: creating a claim
May 11 13:34:35.873: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:34:35.884: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iokrg8n] to have phase Bound
May 11 13:34:35.890: INFO: PersistentVolumeClaim hostpath.csi.k8s.iokrg8n found but phase is Pending instead of Bound.
May 11 13:34:37.894: INFO: PersistentVolumeClaim hostpath.csi.k8s.iokrg8n found and phase=Bound (2.01010091s)
STEP: starting a pod to use the claim
May 11 13:34:37.904: INFO: Waiting up to 15m0s for pod "pvc-snapshottable-tester-9h9tt" in namespace "snapshotting-7184" to be "Succeeded or Failed"
May 11 13:34:37.909: INFO: Pod "pvc-snapshottable-tester-9h9tt": Phase="Pending", Reason="", readiness=false. Elapsed: 5.100401ms
May 11 13:34:39.918: INFO: Pod "pvc-snapshottable-tester-9h9tt": Phase="Pending", Reason="", readiness=false. Elapsed: 2.014023176s
May 11 13:34:41.921: INFO: Pod "pvc-snapshottable-tester-9h9tt": Phase="Pending", Reason="", readiness=false. Elapsed: 4.017337424s
May 11 13:34:43.925: INFO: Pod "pvc-snapshottable-tester-9h9tt": Phase="Pending", Reason="", readiness=false. Elapsed: 6.021272999s
May 11 13:34:45.929: INFO: Pod "pvc-snapshottable-tester-9h9tt": Phase="Pending", Reason="", readiness=false. Elapsed: 8.024742573s
May 11 13:34:47.932: INFO: Pod "pvc-snapshottable-tester-9h9tt": Phase="Pending", Reason="", readiness=false. Elapsed: 10.028423769s
May 11 13:34:50.129: INFO: Pod "pvc-snapshottable-tester-9h9tt": Phase="Pending", Reason="", readiness=false. Elapsed: 12.225293461s
May 11 13:34:52.133: INFO: Pod "pvc-snapshottable-tester-9h9tt": Phase="Succeeded", Reason="", readiness=false. Elapsed: 14.228466134s
STEP: Saw pod success
May 11 13:34:52.133: INFO: Pod "pvc-snapshottable-tester-9h9tt" satisfied condition "Succeeded or Failed"
May 11 13:34:52.531: INFO: Pod pvc-snapshottable-tester-9h9tt has the following logs: 
May 11 13:34:52.531: INFO: Deleting pod "pvc-snapshottable-tester-9h9tt" in namespace "snapshotting-7184"
May 11 13:34:52.538: INFO: Wait up to 5m0s for pod "pvc-snapshottable-tester-9h9tt" to be fully deleted
May 11 13:34:52.542: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iokrg8n] to have phase Bound
May 11 13:34:52.546: INFO: PersistentVolumeClaim hostpath.csi.k8s.iokrg8n found and phase=Bound (4.051827ms)
STEP: checking the claim
... skipping 11 lines ...
[It] should check snapshot fields, check restore correctly works after modifying source data, check deletion
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
STEP: checking the snapshot
STEP: checking the SnapshotContent
STEP: Modifying source data test
STEP: modifying the data in the source PVC
May 11 13:34:54.637: INFO: Waiting up to 15m0s for pod "pvc-snapshottable-data-tester-hrb7b" in namespace "snapshotting-7184" to be "Succeeded or Failed"
May 11 13:34:54.642: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 4.988037ms
May 11 13:34:56.648: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 2.010372177s
May 11 13:34:58.652: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 4.015112279s
May 11 13:35:00.657: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 6.019441925s
May 11 13:35:02.662: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 8.02447045s
May 11 13:35:04.667: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 10.029699961s
May 11 13:35:06.673: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 12.035392505s
May 11 13:35:08.984: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 14.346503174s
May 11 13:35:10.987: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 16.350285885s
May 11 13:35:12.991: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 18.353840001s
May 11 13:35:14.994: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Pending", Reason="", readiness=false. Elapsed: 20.357303615s
May 11 13:35:16.998: INFO: Pod "pvc-snapshottable-data-tester-hrb7b": Phase="Succeeded", Reason="", readiness=false. Elapsed: 22.360605165s
STEP: Saw pod success
May 11 13:35:16.998: INFO: Pod "pvc-snapshottable-data-tester-hrb7b" satisfied condition "Succeeded or Failed"
May 11 13:35:17.002: INFO: Pod pvc-snapshottable-data-tester-hrb7b has the following logs: 
May 11 13:35:17.002: INFO: Deleting pod "pvc-snapshottable-data-tester-hrb7b" in namespace "snapshotting-7184"
May 11 13:35:17.010: INFO: Wait up to 5m0s for pod "pvc-snapshottable-data-tester-hrb7b" to be fully deleted
STEP: creating a pvc from the snapshot
STEP: starting a pod to use the claim
May 11 13:35:29.039: INFO: Running '/usr/local/bin/kubectl --server=https://127.0.0.1:34123 --kubeconfig=/root/.kube/config --namespace=snapshotting-7184 exec restored-pvc-tester-mg8xh --namespace=snapshotting-7184 -- cat /mnt/test/data'
... skipping 43 lines ...
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:121
      
      /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:196
        should check snapshot fields, check restore correctly works after modifying source data, check deletion
        /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic Snapshot (delete policy)] snapshottable[Feature:VolumeSnapshotDataSource] volume snapshot controller  should check snapshot fields, check restore correctly works after modifying source data, check deletion","total":-1,"completed":1,"skipped":351,"failed":0}
May 11 13:36:18.312: INFO: Running AfterSuite actions on all nodes


External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Pre-provisioned Snapshot (delete policy)] snapshottable[Feature:VolumeSnapshotDataSource] volume snapshot controller  
  should check snapshot fields, check restore correctly works after modifying source data, check deletion
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
... skipping 17 lines ...
STEP: creating a claim
May 11 13:34:37.221: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:34:37.230: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.io2lm4g] to have phase Bound
May 11 13:34:37.238: INFO: PersistentVolumeClaim hostpath.csi.k8s.io2lm4g found but phase is Pending instead of Bound.
May 11 13:34:39.241: INFO: PersistentVolumeClaim hostpath.csi.k8s.io2lm4g found and phase=Bound (2.011213567s)
STEP: starting a pod to use the claim
May 11 13:34:39.250: INFO: Waiting up to 15m0s for pod "pvc-snapshottable-tester-spj7t" in namespace "snapshotting-1436" to be "Succeeded or Failed"
May 11 13:34:39.252: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Pending", Reason="", readiness=false. Elapsed: 2.503656ms
May 11 13:34:41.256: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Pending", Reason="", readiness=false. Elapsed: 2.006608406s
May 11 13:34:43.260: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Pending", Reason="", readiness=false. Elapsed: 4.010337584s
May 11 13:34:45.264: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Pending", Reason="", readiness=false. Elapsed: 6.013841467s
May 11 13:34:47.477: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Pending", Reason="", readiness=false. Elapsed: 8.226952454s
May 11 13:34:49.480: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Pending", Reason="", readiness=false. Elapsed: 10.230220583s
May 11 13:34:51.484: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Pending", Reason="", readiness=false. Elapsed: 12.234255387s
May 11 13:34:53.487: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Running", Reason="", readiness=true. Elapsed: 14.236907173s
May 11 13:34:55.494: INFO: Pod "pvc-snapshottable-tester-spj7t": Phase="Succeeded", Reason="", readiness=false. Elapsed: 16.244071057s
STEP: Saw pod success
May 11 13:34:55.494: INFO: Pod "pvc-snapshottable-tester-spj7t" satisfied condition "Succeeded or Failed"
May 11 13:34:55.505: INFO: Pod pvc-snapshottable-tester-spj7t has the following logs: 
May 11 13:34:55.505: INFO: Deleting pod "pvc-snapshottable-tester-spj7t" in namespace "snapshotting-1436"
May 11 13:34:55.521: INFO: Wait up to 5m0s for pod "pvc-snapshottable-tester-spj7t" to be fully deleted
May 11 13:34:55.526: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.io2lm4g] to have phase Bound
May 11 13:34:55.530: INFO: PersistentVolumeClaim hostpath.csi.k8s.io2lm4g found and phase=Bound (3.373062ms)
STEP: checking the claim
... skipping 32 lines ...
[It] should check snapshot fields, check restore correctly works after modifying source data, check deletion
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
STEP: checking the snapshot
STEP: checking the SnapshotContent
STEP: Modifying source data test
STEP: modifying the data in the source PVC
May 11 13:35:03.768: INFO: Waiting up to 15m0s for pod "pvc-snapshottable-data-tester-98cxl" in namespace "snapshotting-1436" to be "Succeeded or Failed"
May 11 13:35:03.773: INFO: Pod "pvc-snapshottable-data-tester-98cxl": Phase="Pending", Reason="", readiness=false. Elapsed: 4.471549ms
May 11 13:35:05.778: INFO: Pod "pvc-snapshottable-data-tester-98cxl": Phase="Pending", Reason="", readiness=false. Elapsed: 2.009600495s
May 11 13:35:07.782: INFO: Pod "pvc-snapshottable-data-tester-98cxl": Phase="Pending", Reason="", readiness=false. Elapsed: 4.013316017s
May 11 13:35:09.786: INFO: Pod "pvc-snapshottable-data-tester-98cxl": Phase="Pending", Reason="", readiness=false. Elapsed: 6.018088128s
May 11 13:35:11.790: INFO: Pod "pvc-snapshottable-data-tester-98cxl": Phase="Succeeded", Reason="", readiness=false. Elapsed: 8.022180982s
STEP: Saw pod success
May 11 13:35:11.790: INFO: Pod "pvc-snapshottable-data-tester-98cxl" satisfied condition "Succeeded or Failed"
May 11 13:35:11.796: INFO: Pod pvc-snapshottable-data-tester-98cxl has the following logs: 
May 11 13:35:11.796: INFO: Deleting pod "pvc-snapshottable-data-tester-98cxl" in namespace "snapshotting-1436"
May 11 13:35:11.809: INFO: Wait up to 5m0s for pod "pvc-snapshottable-data-tester-98cxl" to be fully deleted
STEP: creating a pvc from the snapshot
STEP: starting a pod to use the claim
May 11 13:35:21.843: INFO: Running '/usr/local/bin/kubectl --server=https://127.0.0.1:34123 --kubeconfig=/root/.kube/config --namespace=snapshotting-1436 exec restored-pvc-tester-gpjws --namespace=snapshotting-1436 -- cat /mnt/test/data'
... skipping 43 lines ...
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:121
      
      /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:196
        should check snapshot fields, check restore correctly works after modifying source data, check deletion
        /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Pre-provisioned Snapshot (delete policy)] snapshottable[Feature:VolumeSnapshotDataSource] volume snapshot controller  should check snapshot fields, check restore correctly works after modifying source data, check deletion","total":-1,"completed":1,"skipped":1160,"failed":0}
May 11 13:36:27.820: INFO: Running AfterSuite actions on all nodes


External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Pre-provisioned Snapshot (retain policy)] snapshottable[Feature:VolumeSnapshotDataSource] volume snapshot controller  
  should check snapshot fields, check restore correctly works after modifying source data, check deletion
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
... skipping 17 lines ...
STEP: creating a claim
May 11 13:34:37.015: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:34:37.025: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iowtjtx] to have phase Bound
May 11 13:34:37.031: INFO: PersistentVolumeClaim hostpath.csi.k8s.iowtjtx found but phase is Pending instead of Bound.
May 11 13:34:39.035: INFO: PersistentVolumeClaim hostpath.csi.k8s.iowtjtx found and phase=Bound (2.009644706s)
STEP: starting a pod to use the claim
May 11 13:34:39.043: INFO: Waiting up to 15m0s for pod "pvc-snapshottable-tester-4sn5h" in namespace "snapshotting-1496" to be "Succeeded or Failed"
May 11 13:34:39.046: INFO: Pod "pvc-snapshottable-tester-4sn5h": Phase="Pending", Reason="", readiness=false. Elapsed: 2.631271ms
May 11 13:34:41.049: INFO: Pod "pvc-snapshottable-tester-4sn5h": Phase="Pending", Reason="", readiness=false. Elapsed: 2.006118809s
May 11 13:34:43.053: INFO: Pod "pvc-snapshottable-tester-4sn5h": Phase="Pending", Reason="", readiness=false. Elapsed: 4.009341667s
May 11 13:34:45.056: INFO: Pod "pvc-snapshottable-tester-4sn5h": Phase="Pending", Reason="", readiness=false. Elapsed: 6.01259236s
May 11 13:34:47.107: INFO: Pod "pvc-snapshottable-tester-4sn5h": Phase="Pending", Reason="", readiness=false. Elapsed: 8.063734474s
May 11 13:34:49.213: INFO: Pod "pvc-snapshottable-tester-4sn5h": Phase="Pending", Reason="", readiness=false. Elapsed: 10.169570829s
May 11 13:34:51.216: INFO: Pod "pvc-snapshottable-tester-4sn5h": Phase="Pending", Reason="", readiness=false. Elapsed: 12.172600225s
May 11 13:34:53.219: INFO: Pod "pvc-snapshottable-tester-4sn5h": Phase="Succeeded", Reason="", readiness=false. Elapsed: 14.176145181s
STEP: Saw pod success
May 11 13:34:53.219: INFO: Pod "pvc-snapshottable-tester-4sn5h" satisfied condition "Succeeded or Failed"
May 11 13:34:53.226: INFO: Pod pvc-snapshottable-tester-4sn5h has the following logs: 
May 11 13:34:53.226: INFO: Deleting pod "pvc-snapshottable-tester-4sn5h" in namespace "snapshotting-1496"
May 11 13:34:53.236: INFO: Wait up to 5m0s for pod "pvc-snapshottable-tester-4sn5h" to be fully deleted
May 11 13:34:53.239: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.iowtjtx] to have phase Bound
May 11 13:34:53.243: INFO: PersistentVolumeClaim hostpath.csi.k8s.iowtjtx found and phase=Bound (4.193093ms)
STEP: checking the claim
... skipping 32 lines ...
[It] should check snapshot fields, check restore correctly works after modifying source data, check deletion
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
STEP: checking the snapshot
STEP: checking the SnapshotContent
STEP: Modifying source data test
STEP: modifying the data in the source PVC
May 11 13:35:01.469: INFO: Waiting up to 15m0s for pod "pvc-snapshottable-data-tester-rf6tj" in namespace "snapshotting-1496" to be "Succeeded or Failed"
May 11 13:35:01.473: INFO: Pod "pvc-snapshottable-data-tester-rf6tj": Phase="Pending", Reason="", readiness=false. Elapsed: 3.986482ms
May 11 13:35:03.478: INFO: Pod "pvc-snapshottable-data-tester-rf6tj": Phase="Pending", Reason="", readiness=false. Elapsed: 2.00923085s
May 11 13:35:05.483: INFO: Pod "pvc-snapshottable-data-tester-rf6tj": Phase="Pending", Reason="", readiness=false. Elapsed: 4.013815986s
May 11 13:35:07.487: INFO: Pod "pvc-snapshottable-data-tester-rf6tj": Phase="Pending", Reason="", readiness=false. Elapsed: 6.017386824s
May 11 13:35:09.494: INFO: Pod "pvc-snapshottable-data-tester-rf6tj": Phase="Pending", Reason="", readiness=false. Elapsed: 8.024398776s
May 11 13:35:11.498: INFO: Pod "pvc-snapshottable-data-tester-rf6tj": Phase="Succeeded", Reason="", readiness=false. Elapsed: 10.028609285s
STEP: Saw pod success
May 11 13:35:11.498: INFO: Pod "pvc-snapshottable-data-tester-rf6tj" satisfied condition "Succeeded or Failed"
May 11 13:35:11.504: INFO: Pod pvc-snapshottable-data-tester-rf6tj has the following logs: 
May 11 13:35:11.505: INFO: Deleting pod "pvc-snapshottable-data-tester-rf6tj" in namespace "snapshotting-1496"
May 11 13:35:11.516: INFO: Wait up to 5m0s for pod "pvc-snapshottable-data-tester-rf6tj" to be fully deleted
STEP: creating a pvc from the snapshot
STEP: starting a pod to use the claim
May 11 13:35:21.546: INFO: Running '/usr/local/bin/kubectl --server=https://127.0.0.1:34123 --kubeconfig=/root/.kube/config --namespace=snapshotting-1496 exec restored-pvc-tester-tvckj --namespace=snapshotting-1496 -- cat /mnt/test/data'
... skipping 35 lines ...
May 11 13:35:48.380: INFO: volumesnapshotcontents pre-provisioned-snapcontent-566b2c28-4a1e-4a4c-afde-88d8506316d2 has been found and is not deleted
May 11 13:35:49.384: INFO: volumesnapshotcontents pre-provisioned-snapcontent-566b2c28-4a1e-4a4c-afde-88d8506316d2 has been found and is not deleted
May 11 13:35:50.388: INFO: volumesnapshotcontents pre-provisioned-snapcontent-566b2c28-4a1e-4a4c-afde-88d8506316d2 has been found and is not deleted
May 11 13:35:51.392: INFO: volumesnapshotcontents pre-provisioned-snapcontent-566b2c28-4a1e-4a4c-afde-88d8506316d2 has been found and is not deleted
May 11 13:35:52.395: INFO: volumesnapshotcontents pre-provisioned-snapcontent-566b2c28-4a1e-4a4c-afde-88d8506316d2 has been found and is not deleted
May 11 13:35:53.400: INFO: volumesnapshotcontents pre-provisioned-snapcontent-566b2c28-4a1e-4a4c-afde-88d8506316d2 has been found and is not deleted
May 11 13:35:54.400: INFO: WaitUntil failed after reaching the timeout 30s
[AfterEach] volume snapshot controller
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:192
May 11 13:35:54.405: INFO: Pod restored-pvc-tester-tvckj has the following logs: 
May 11 13:35:54.405: INFO: Deleting pod "restored-pvc-tester-tvckj" in namespace "snapshotting-1496"
May 11 13:35:54.410: INFO: Wait up to 5m0s for pod "restored-pvc-tester-tvckj" to be fully deleted
May 11 13:36:32.417: INFO: deleting claim "snapshotting-1496"/"pvc-2nltk"
... skipping 54 lines ...
STEP: creating a claim
May 11 13:34:35.372: INFO: Warning: Making PVC: VolumeMode specified as invalid empty string, treating as nil
May 11 13:34:35.396: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.ioj6n6v] to have phase Bound
May 11 13:34:35.416: INFO: PersistentVolumeClaim hostpath.csi.k8s.ioj6n6v found but phase is Pending instead of Bound.
May 11 13:34:37.420: INFO: PersistentVolumeClaim hostpath.csi.k8s.ioj6n6v found and phase=Bound (2.02257132s)
STEP: starting a pod to use the claim
May 11 13:34:37.431: INFO: Waiting up to 15m0s for pod "pvc-snapshottable-tester-p4cpf" in namespace "snapshotting-2895" to be "Succeeded or Failed"
May 11 13:34:37.434: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 2.873726ms
May 11 13:34:39.438: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 2.006892718s
May 11 13:34:41.441: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 4.009735819s
May 11 13:34:43.445: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 6.013402582s
May 11 13:34:45.449: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 8.017178407s
May 11 13:34:47.477: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 10.045250958s
May 11 13:34:49.480: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 12.048922067s
May 11 13:34:51.484: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 14.052942693s
May 11 13:34:53.487: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 16.055691214s
May 11 13:34:55.494: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 18.062306149s
May 11 13:34:57.503: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Pending", Reason="", readiness=false. Elapsed: 20.071900491s
May 11 13:34:59.509: INFO: Pod "pvc-snapshottable-tester-p4cpf": Phase="Succeeded", Reason="", readiness=false. Elapsed: 22.077411423s
STEP: Saw pod success
May 11 13:34:59.509: INFO: Pod "pvc-snapshottable-tester-p4cpf" satisfied condition "Succeeded or Failed"
May 11 13:34:59.517: INFO: Pod pvc-snapshottable-tester-p4cpf has the following logs: 
May 11 13:34:59.517: INFO: Deleting pod "pvc-snapshottable-tester-p4cpf" in namespace "snapshotting-2895"
May 11 13:34:59.531: INFO: Wait up to 5m0s for pod "pvc-snapshottable-tester-p4cpf" to be fully deleted
May 11 13:34:59.536: INFO: Waiting up to 5m0s for PersistentVolumeClaims [hostpath.csi.k8s.ioj6n6v] to have phase Bound
May 11 13:34:59.539: INFO: PersistentVolumeClaim hostpath.csi.k8s.ioj6n6v found and phase=Bound (3.014268ms)
STEP: checking the claim
... skipping 12 lines ...
[It] should check snapshot fields, check restore correctly works after modifying source data, check deletion
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
STEP: checking the snapshot
STEP: checking the SnapshotContent
STEP: Modifying source data test
STEP: modifying the data in the source PVC
May 11 13:35:03.622: INFO: Waiting up to 15m0s for pod "pvc-snapshottable-data-tester-jhqb9" in namespace "snapshotting-2895" to be "Succeeded or Failed"
May 11 13:35:03.626: INFO: Pod "pvc-snapshottable-data-tester-jhqb9": Phase="Pending", Reason="", readiness=false. Elapsed: 3.579152ms
May 11 13:35:05.631: INFO: Pod "pvc-snapshottable-data-tester-jhqb9": Phase="Pending", Reason="", readiness=false. Elapsed: 2.008294084s
May 11 13:35:07.634: INFO: Pod "pvc-snapshottable-data-tester-jhqb9": Phase="Pending", Reason="", readiness=false. Elapsed: 4.011906209s
May 11 13:35:09.638: INFO: Pod "pvc-snapshottable-data-tester-jhqb9": Phase="Pending", Reason="", readiness=false. Elapsed: 6.015728515s
May 11 13:35:11.643: INFO: Pod "pvc-snapshottable-data-tester-jhqb9": Phase="Succeeded", Reason="", readiness=false. Elapsed: 8.020304838s
STEP: Saw pod success
May 11 13:35:11.643: INFO: Pod "pvc-snapshottable-data-tester-jhqb9" satisfied condition "Succeeded or Failed"
May 11 13:35:11.648: INFO: Pod pvc-snapshottable-data-tester-jhqb9 has the following logs: 
May 11 13:35:11.648: INFO: Deleting pod "pvc-snapshottable-data-tester-jhqb9" in namespace "snapshotting-2895"
May 11 13:35:11.659: INFO: Wait up to 5m0s for pod "pvc-snapshottable-data-tester-jhqb9" to be fully deleted
STEP: creating a pvc from the snapshot
STEP: starting a pod to use the claim
May 11 13:35:23.693: INFO: Running '/usr/local/bin/kubectl --server=https://127.0.0.1:34123 --kubeconfig=/root/.kube/config --namespace=snapshotting-2895 exec restored-pvc-tester-jllng --namespace=snapshotting-2895 -- cat /mnt/test/data'
... skipping 35 lines ...
May 11 13:35:50.388: INFO: volumesnapshotcontents snapcontent-33d6ea07-0b3b-4e19-a35f-3e39d11a8f72 has been found and is not deleted
May 11 13:35:51.392: INFO: volumesnapshotcontents snapcontent-33d6ea07-0b3b-4e19-a35f-3e39d11a8f72 has been found and is not deleted
May 11 13:35:52.396: INFO: volumesnapshotcontents snapcontent-33d6ea07-0b3b-4e19-a35f-3e39d11a8f72 has been found and is not deleted
May 11 13:35:53.400: INFO: volumesnapshotcontents snapcontent-33d6ea07-0b3b-4e19-a35f-3e39d11a8f72 has been found and is not deleted
May 11 13:35:54.404: INFO: volumesnapshotcontents snapcontent-33d6ea07-0b3b-4e19-a35f-3e39d11a8f72 has been found and is not deleted
May 11 13:35:55.408: INFO: volumesnapshotcontents snapcontent-33d6ea07-0b3b-4e19-a35f-3e39d11a8f72 has been found and is not deleted
May 11 13:35:56.408: INFO: WaitUntil failed after reaching the timeout 30s
[AfterEach] volume snapshot controller
  /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:192
May 11 13:35:56.413: INFO: Pod restored-pvc-tester-jllng has the following logs: 
May 11 13:35:56.414: INFO: Deleting pod "restored-pvc-tester-jllng" in namespace "snapshotting-2895"
May 11 13:35:56.418: INFO: Wait up to 5m0s for pod "restored-pvc-tester-jllng" to be fully deleted
May 11 13:37:22.427: INFO: deleting claim "snapshotting-2895"/"pvc-fmnlh"
... skipping 28 lines ...
    /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:121
      
      /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:196
        should check snapshot fields, check restore correctly works after modifying source data, check deletion
        /home/prow/go/src/k8s.io/kubernetes/_output/local/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/snapshottable.go:213
------------------------------
{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Dynamic Snapshot (retain policy)] snapshottable[Feature:VolumeSnapshotDataSource] volume snapshot controller  should check snapshot fields, check restore correctly works after modifying source data, check deletion","total":-1,"completed":1,"skipped":142,"failed":0}
May 11 13:37:30.200: INFO: Running AfterSuite actions on all nodes


{"msg":"PASSED External Storage [Driver: hostpath.csi.k8s.io] [Testpattern: Pre-provisioned Snapshot (retain policy)] snapshottable[Feature:VolumeSnapshotDataSource] volume snapshot controller  should check snapshot fields, check restore correctly works after modifying source data, check deletion","total":-1,"completed":1,"skipped":1029,"failed":0}
May 11 13:36:39.510: INFO: Running AfterSuite actions on all nodes
May 11 13:37:30.264: INFO: Running AfterSuite actions on node 1
May 11 13:37:30.264: INFO: Dumping logs locally to: /logs/artifacts
May 11 13:37:30.264: INFO: Error running cluster/log-dump/log-dump.sh: fork/exec ../../cluster/log-dump/log-dump.sh: no such file or directory


Ran 6 of 5870 Specs in 175.783 seconds
SUCCESS! -- 6 Passed | 0 Failed | 0 Pending | 5864 Skipped


Ginkgo ran 1 suite in 2m59.313154005s
Test Suite Passed
Tue May 11 13:37:30 UTC 2021 go1.16.4 /home/prow/go/src/k8s.io/kubernetes$ go run /home/prow/go/src/github.com/kubernetes-csi/external-provisioner/release-tools/filter-junit.go -t=External Storage -o /logs/artifacts/junit_parallel-features.xml /logs/artifacts/junit_01.xml /logs/artifacts/junit_02.xml /logs/artifacts/junit_03.xml /logs/artifacts/junit_04.xml /logs/artifacts/junit_05.xml /logs/artifacts/junit_06.xml /logs/artifacts/junit_07.xml
Tue May 11 13:37:30 UTC 2021 go1.16.4 $ kind export logs --name=csi-prow /logs/artifacts/cluster-logs/non-alpha
... skipping 20 lines ...