This job view page is being replaced by Spyglass soon. Check out the new job view.
ResultFAILURE
Tests 4 failed / 779 succeeded
Started2023-03-04 09:13
Elapsed37m5s
Revisionmaster

Test Failures


Kubernetes e2e suite [sig-api-machinery] AdmissionWebhook [Privileged:ClusterAdmin] should honor timeout [Conformance] 5m5s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-api\-machinery\]\sAdmissionWebhook\s\[Privileged\:ClusterAdmin\]\sshould\shonor\stimeout\s\[Conformance\]$'
/workspace/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/apimachinery/webhook.go:87
Mar  4 09:33:37.080: waiting for the deployment status valid%!(EXTRA string=k8s.gcr.io/e2e-test-images/agnhost:2.39, string=sample-webhook-deployment, string=webhook-1731)
Unexpected error:
    <*errors.errorString | 0xc0024cc930>: {
        s: "error waiting for deployment \"sample-webhook-deployment\" status to match expectation: deployment status: v1.DeploymentStatus{ObservedGeneration:1, Replicas:1, UpdatedReplicas:1, ReadyReplicas:0, AvailableReplicas:0, UnavailableReplicas:1, Conditions:[]v1.DeploymentCondition{v1.DeploymentCondition{Type:\"Available\", Status:\"False\", LastUpdateTime:time.Date(2023, time.March, 4, 9, 28, 36, 0, time.Local), LastTransitionTime:time.Date(2023, time.March, 4, 9, 28, 36, 0, time.Local), Reason:\"MinimumReplicasUnavailable\", Message:\"Deployment does not have minimum availability.\"}, v1.DeploymentCondition{Type:\"Progressing\", Status:\"True\", LastUpdateTime:time.Date(2023, time.March, 4, 9, 28, 36, 0, time.Local), LastTransitionTime:time.Date(2023, time.March, 4, 9, 28, 36, 0, time.Local), Reason:\"ReplicaSetUpdated\", Message:\"ReplicaSet \\\"sample-webhook-deployment-6c69dbd86b\\\" is progressing.\"}}, CollisionCount:(*int32)(nil)}",
    }
    error waiting for deployment "sample-webhook-deployment" status to match expectation: deployment status: v1.DeploymentStatus{ObservedGeneration:1, Replicas:1, UpdatedReplicas:1, ReadyReplicas:0, AvailableReplicas:0, UnavailableReplicas:1, Conditions:[]v1.DeploymentCondition{v1.DeploymentCondition{Type:"Available", Status:"False", LastUpdateTime:time.Date(2023, time.March, 4, 9, 28, 36, 0, time.Local), LastTransitionTime:time.Date(2023, time.March, 4, 9, 28, 36, 0, time.Local), Reason:"MinimumReplicasUnavailable", Message:"Deployment does not have minimum availability."}, v1.DeploymentCondition{Type:"Progressing", Status:"True", LastUpdateTime:time.Date(2023, time.March, 4, 9, 28, 36, 0, time.Local), LastTransitionTime:time.Date(2023, time.March, 4, 9, 28, 36, 0, time.Local), Reason:"ReplicaSetUpdated", Message:"ReplicaSet \"sample-webhook-deployment-6c69dbd86b\" is progressing."}}, CollisionCount:(*int32)(nil)}
occurred
/workspace/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/apimachinery/webhook.go:824
				
				Click to see stdout/stderrfrom junit_20.xml

Filter through log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: local][LocalVolumeType: block] [Testpattern: Pre-provisioned PV (default fs)] subPath should be able to unmount after the subpath directory is deleted [LinuxOnly] 5m27s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\slocal\]\[LocalVolumeType\:\sblock\]\s\[Testpattern\:\sPre\-provisioned\sPV\s\(default\sfs\)\]\ssubPath\sshould\sbe\sable\sto\sunmount\safter\sthe\ssubpath\sdirectory\sis\sdeleted\s\[LinuxOnly\]$'
/workspace/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:445
Mar  4 09:33:48.926: while waiting for pod to be running
Unexpected error:
    <*errors.errorString | 0xc000230210>: {
        s: "timed out waiting for the condition",
    }
    timed out waiting for the condition
occurred
/workspace/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:465
				
				Click to see stdout/stderrfrom junit_10.xml

Find to mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] PersistentVolumes-local [Volume type: dir-link-bindmounted] Two pods mounting a local volume at the same time should be able to write from pod1 and read from pod2 5m16s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sPersistentVolumes\-local\s\s\[Volume\stype\:\sdir\-link\-bindmounted\]\sTwo\spods\smounting\sa\slocal\svolume\sat\sthe\ssame\stime\sshould\sbe\sable\sto\swrite\sfrom\spod1\sand\sread\sfrom\spod2$'
/workspace/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/persistent_volumes-local.go:249
Mar  4 09:33:33.073: Unexpected error:
    <*errors.errorString | 0xc0015249b0>: {
        s: "pod \"pod-3f633ea9-ac20-48eb-97c5-e97e7a3e1c4f\" is not Running: timed out waiting for the condition",
    }
    pod "pod-3f633ea9-ac20-48eb-97c5-e97e7a3e1c4f" is not Running: timed out waiting for the condition
occurred
/workspace/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/persistent_volumes-local.go:749
				
				Click to see stdout/stderrfrom junit_04.xml

Find pod-3f633ea9-ac20-48eb-97c5-e97e7a3e1c4f mentions in log files | View test history on testgrid


kubetest2 Test 24m53s

exit status 255
				from junit_runner.xml

Filter through log files | View test history on testgrid


Show 779 Passed Tests

Show 6528 Skipped Tests