This job view page is being replaced by Spyglass soon. Check out the new job view.
ResultFAILURE
Tests 12 failed / 284 succeeded
Started2021-09-22 01:37
Elapsed1h5m
Revisionmaster
job-versionv1.21.6-rc.0.7+eb8422186e4bad
kubetest-version
master_os_imagecos-85-13310-1041-9
node_os_imagecos-85-13310-1041-9
revisionv1.21.6-rc.0.7+eb8422186e4bad

Test Failures


Kubernetes e2e suite [sig-node] Probing container should *not* be restarted with a tcp:8080 liveness probe [NodeConformance] [Conformance] 4m17s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-node\]\sProbing\scontainer\sshould\s\*not\*\sbe\srestarted\swith\sa\stcp\:8080\sliveness\sprobe\s\[NodeConformance\]\s\[Conformance\]$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/framework/framework.go:630
Sep 22 02:12:16.821: pod container-probe-4479/liveness-5fa1215c-dd01-4153-832c-537078413e00 - expected number of restarts: 0, found restarts: 1
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/common/node/container_probe.go:178
				
				Click to see stdout/stderrfrom junit_06.xml

Find container-probe-4479/liveness-5fa1215c-dd01-4153-832c-537078413e00 mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Dynamic PV (ntfs)][Feature:Windows] subPath should support existing directories when readOnly specified in the volumeSource 5m39s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sDynamic\sPV\s\(ntfs\)\]\[Feature\:Windows\]\ssubPath\sshould\ssupport\sexisting\sdirectories\swhen\sreadOnly\sspecified\sin\sthe\svolumeSource$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:399
Sep 22 02:13:55.818: Unexpected error:
    <*errors.errorString | 0xc004013a30>: {
        s: "expected pod \"pod-subpath-test-dynamicpv-b52d\" success: Gave up after waiting 5m0s for pod \"pod-subpath-test-dynamicpv-b52d\" to be \"Succeeded or Failed\"",
    }
    expected pod "pod-subpath-test-dynamicpv-b52d" success: Gave up after waiting 5m0s for pod "pod-subpath-test-dynamicpv-b52d" to be "Succeeded or Failed"
occurred
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/framework/util.go:742
				
				Click to see stdout/stderrfrom junit_01.xml

Find pod-subpath-test-dynamicpv-b52d mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Dynamic PV (ntfs)][Feature:Windows] subPath should support existing directory 5m38s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sDynamic\sPV\s\(ntfs\)\]\[Feature\:Windows\]\ssubPath\sshould\ssupport\sexisting\sdirectory$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:205
Sep 22 02:15:51.294: Unexpected error:
    <*errors.errorString | 0xc002e74eb0>: {
        s: "expected pod \"pod-subpath-test-dynamicpv-sshq\" success: Gave up after waiting 5m0s for pod \"pod-subpath-test-dynamicpv-sshq\" to be \"Succeeded or Failed\"",
    }
    expected pod "pod-subpath-test-dynamicpv-sshq" success: Gave up after waiting 5m0s for pod "pod-subpath-test-dynamicpv-sshq" to be "Succeeded or Failed"
occurred
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/framework/util.go:742
				
				Click to see stdout/stderrfrom junit_03.xml

Find pod-subpath-test-dynamicpv-sshq mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Dynamic PV (ntfs)][Feature:Windows] subPath should support non-existent path 5m26s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sDynamic\sPV\s\(ntfs\)\]\[Feature\:Windows\]\ssubPath\sshould\ssupport\snon\-existent\spath$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:194
Sep 22 02:25:50.758: Unexpected error:
    <*errors.errorString | 0xc0009d3020>: {
        s: "expected pod \"pod-subpath-test-dynamicpv-cgfp\" success: Gave up after waiting 5m0s for pod \"pod-subpath-test-dynamicpv-cgfp\" to be \"Succeeded or Failed\"",
    }
    expected pod "pod-subpath-test-dynamicpv-cgfp" success: Gave up after waiting 5m0s for pod "pod-subpath-test-dynamicpv-cgfp" to be "Succeeded or Failed"
occurred
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/framework/util.go:742
				
				Click to see stdout/stderrfrom junit_02.xml

Find pod-subpath-test-dynamicpv-cgfp mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Dynamic PV (ntfs)][Feature:Windows] subPath should support readOnly directory specified in the volumeMount 5m43s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sDynamic\sPV\s\(ntfs\)\]\[Feature\:Windows\]\ssubPath\sshould\ssupport\sreadOnly\sdirectory\sspecified\sin\sthe\svolumeMount$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/subpath.go:369
Sep 22 02:19:22.841: Unexpected error:
    <*errors.errorString | 0xc00155eb30>: {
        s: "expected pod \"pod-subpath-test-dynamicpv-kqtb\" success: Gave up after waiting 5m0s for pod \"pod-subpath-test-dynamicpv-kqtb\" to be \"Succeeded or Failed\"",
    }
    expected pod "pod-subpath-test-dynamicpv-kqtb" success: Gave up after waiting 5m0s for pod "pod-subpath-test-dynamicpv-kqtb" to be "Succeeded or Failed"
occurred
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/framework/util.go:742
				
				Click to see stdout/stderrfrom junit_06.xml

Find pod-subpath-test-dynamicpv-kqtb mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Dynamic PV (ntfs)][Feature:Windows] volumes should allow exec of files on the volume 5m29s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sDynamic\sPV\s\(ntfs\)\]\[Feature\:Windows\]\svolumes\sshould\sallow\sexec\sof\sfiles\son\sthe\svolume$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:196
Sep 22 02:26:12.567: Unexpected error:
    <*errors.errorString | 0xc003e7a860>: {
        s: "expected pod \"exec-volume-test-dynamicpv-lbfw\" success: Gave up after waiting 5m0s for pod \"exec-volume-test-dynamicpv-lbfw\" to be \"Succeeded or Failed\"",
    }
    expected pod "exec-volume-test-dynamicpv-lbfw" success: Gave up after waiting 5m0s for pod "exec-volume-test-dynamicpv-lbfw" to be "Succeeded or Failed"
occurred
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/framework/util.go:742
				
				Click to see stdout/stderrfrom junit_08.xml

Find exec-volume-test-dynamicpv-lbfw mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Dynamic PV (ntfs)][Feature:Windows] volumes should store data 5m39s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sDynamic\sPV\s\(ntfs\)\]\[Feature\:Windows\]\svolumes\sshould\sstore\sdata$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:159
Sep 22 02:27:34.368: Failed to create injector pod: timed out waiting for the condition
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:186
				
				Click to see stdout/stderrfrom junit_01.xml

Filter through log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Inline-volume (ntfs)][Feature:Windows] volumes should allow exec of files on the volume 5m26s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sInline\-volume\s\(ntfs\)\]\[Feature\:Windows\]\svolumes\sshould\sallow\sexec\sof\sfiles\son\sthe\svolume$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:196
Sep 22 02:12:46.456: Unexpected error:
    <*errors.errorString | 0xc0035d8e10>: {
        s: "expected pod \"exec-volume-test-inlinevolume-6fpm\" success: Gave up after waiting 5m0s for pod \"exec-volume-test-inlinevolume-6fpm\" to be \"Succeeded or Failed\"",
    }
    expected pod "exec-volume-test-inlinevolume-6fpm" success: Gave up after waiting 5m0s for pod "exec-volume-test-inlinevolume-6fpm" to be "Succeeded or Failed"
occurred
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/framework/util.go:742
				
				Click to see stdout/stderrfrom junit_05.xml

Find exec-volume-test-inlinevolume-6fpm mentions in log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Inline-volume (ntfs)][Feature:Windows] volumes should store data 5m32s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sInline\-volume\s\(ntfs\)\]\[Feature\:Windows\]\svolumes\sshould\sstore\sdata$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:159
Sep 22 02:15:00.527: Failed to create injector pod: timed out waiting for the condition
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:186
				
				Click to see stdout/stderrfrom junit_04.xml

Filter through log files | View test history on testgrid


Kubernetes e2e suite [sig-storage] In-tree Volumes [Driver: windows-gcepd] [Testpattern: Pre-provisioned PV (ntfs)][Feature:Windows] volumes should allow exec of files on the volume 5m42s

go run hack/e2e.go -v --test --test_args='--ginkgo.focus=Kubernetes\se2e\ssuite\s\[sig\-storage\]\sIn\-tree\sVolumes\s\[Driver\:\swindows\-gcepd\]\s\[Testpattern\:\sPre\-provisioned\sPV\s\(ntfs\)\]\[Feature\:Windows\]\svolumes\sshould\sallow\sexec\sof\sfiles\son\sthe\svolume$'
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/storage/testsuites/volumes.go:196
Sep 22 02:32:27.694: Unexpected error:
    <*errors.errorString | 0xc003900d50>: {
        s: "expected pod \"exec-volume-test-preprovisionedpv-ctcl\" success: Gave up after waiting 5m0s for pod \"exec-volume-test-preprovisionedpv-ctcl\" to be \"Succeeded or Failed\"",
    }
    expected pod "exec-volume-test-preprovisionedpv-ctcl" success: Gave up after waiting 5m0s for pod "exec-volume-test-preprovisionedpv-ctcl" to be "Succeeded or Failed"
occurred
/go/src/k8s.io/kubernetes/_output/dockerized/go/src/k8s.io/kubernetes/test/e2e/framework/util.go:742